Real time ultrasonography of the gastric antrum.
Open accessThe DOI matches its Crossref record.
Abstract
This study aimed to evaluate whether serial ultrasound measurements of antral volumes are reproducible and, if so, whether they are representative of the entire gastric contents and reliably measure gastric emptying. The antral volume was measured in man after oral and intragastric administration of known amounts of 5% glucose solutions, and on two separate occasions in the same subjects, after the ingestion of a standardised solid-liquid meal (1050 kcal). Antral volume measurements were performed in both supine and upright positions; inter- and intraobserver measurement errors were also assessed. After ingestion or intragastric administration of equal amounts of liquid, antral volumes determined by ultrasound showed a wide intersubject variability. In each individual subject, however, a linear trend was found between the antral volume and amount of ingested or administered liquid. Intrasubject variability of antral volume measurements was at its minimum in fasting conditions and 300 minutes after ingestion of the solid-liquid meal. Intra- and interobserver variations and whether the patient was erect or supine did not affect measurements of antral volumes. These results support the use of real time ultrasound in determining the gastric emptying time. Results at fasting and 300 minutes after a solid-liquid meal are stable end points of measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasound assessment of gastric content and volume
Van de Putte, P., & Perlas, A. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu151 · Cited by 482
Darwiche, G., Almér, L. O., Björgell, O., Cederholm, C., & Nilsson, P. (1999) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1999.18.10.673 · Cited by 131
Simultaneous Measurement of Gastric Emptying of A Solid Meal by Ultrasound and by Scintigraphy
Benini, L., Sembenini, C., Heading, R. C., Giorgetti, P. G., Montemezzi, S., Zamboni, M., De Benedetto, P., Brighenti, F., & Vantini, I. (1999) · American Journal of Gastroenterology · doi:10.1111/j.1572-0241.1999.01429.x · Cited by 88
“Restricting ultrasonographic studies to liquid meals seems reasonable (16) but, in fact, consistent results have been reported with solid meals when experienced operators are involved (11, 17).”
Metadata
- Authors
- Ricci, R., Bontempo, I., Corazziari, E., La Bella, A., & Torsoli, A.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 1993-02
- Volume
- 34
- Issue
- 2
- Pages
- 173-176
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2017282921
- Cited by
- 99
- References
- 0
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real time ultrasonography of the gastric antrum. https://app.cochat.ai/papers/10.1136/gut.34.2.173
- The paper
- Ricci, R., Bontempo, I., Corazziari, E., La Bella, A., & Torsoli, A. (1993). Real time ultrasonography of the gastric antrum. Gut. https://doi.org/10.1136/gut.34.2.173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.