Cited by 131Gastrointestinal motility and disordersEnhanced Recovery After SurgeryGastrointestinal Bleeding Diagnosis and Treatment

Measurement of gastric emptying by standardized real-time ultrasonography in healthy subjects and diabetic patients

Darwiche, G, Almér, L O, Björgell, O, Cederholm, C, Nilsson, P·1999·Journal of Ultrasound in Medicine

Abstract

The aim of this study was to simplify and standardize a reproducible, well-tolerated and clinically applicable method for the assessment of gastric emptying rate by real-time ultrasonography. A total of 33 subjects were examined, including 19 healthy subjects and 14 patients with insulin-dependent diabetes mellitus and clinically suspected delayed gastric emptying. Measurements of the gastric antrum were taken in the supine position and in relation to internal landmarks to obtain a standardized cross-sectional image producing the area of a selected slice of the antrum. Diabetic patients were examined on the condition that the fasting blood glucose level was 3.5 to 9.0 mmol/l. Gastric emptying rate was estimated and expressed as the percentage reduction in antral cross-sectional area from 15 to 90 min after the ingestion of a standardized semisolid breakfast meal (300 g rice pudding, 330 kcal). Interobserver and intraobserver measurement errors were assessed, as was the significance of age and sex on gastric emptying. In comparison to healthy subjects, diabetic patients showed significantly wider median values of the 90 min postprandial antral area, but only a mild tendency toward greater dilation of the gastric antrum prior to and 15 min after meal ingestion. The median value of gastric emptying rate in these diabetic patients was estimated at 29%, which was less than half of that in the healthy subjects (63%). Statistically the difference was highly significant. Interpersonal variability of gastric emptying rate and antral areas was large for both groups. Measurements of gastric emptying rate gave highly reproducible results on separate days and from different observers (interobserver systematic measurement error 0.3% and random measurement error 10.9%; intraobserver systematic measurement error 3.6% and random measurement error 9.5%). No difference in gastric emptying rate was found related to age or sex. We conclude that the use of standardized real-time ultrasonography to determine gastric antral cross-sectional area in a single section of the stomach is a valid method for estimating gastric emptying rate.

Integrity signals

Registry

Crossref · 10.7863/jum.1999.18.10.673

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Darwiche, G., Almér, L. O., Björgell, O., Cederholm, C., & Nilsson, P.
Affiliations
Lund University (SE)
Venue
Journal of Ultrasound in Medicine
Publisher
Wiley
Published
1999-10
Volume
18
Issue
10
Pages
673-682
ISSN
0278-4297 (ISSN-L)
OpenAlex
W2130035141
Cited by
131
References
42
Citations by year
2026: 4 · 2025: 5 · 2024: 3 · 2023: 8 · 2022: 5 · 2021: 6 · 2020: 11 · 2019: 7 · 2018: 1 · 2017: 7 · 2016: 11 · 2015: 6 · 2014: 7 · 2013: 4 · 2012: 4
FWCI
1.88
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Ultrasound in Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Gastroenterology › Gastrointestinal motility and disorders
  • Health Sciences › Medicine › Surgery › Enhanced Recovery After Surgery
  • Health Sciences › Medicine › Gastroenterology › Gastrointestinal Bleeding Diagnosis and Treatment
Keywords
gastric emptying, gastric emptying rate, real-time ultrasound, gastric antrum, antral cross-sectional area, type 1 diabetes, delayed gastric emptying, measurement reproducibility, interobserver variability, postprandial gastric volume, standardized measurement protocol
MeSH terms
Adult, Aged, Clinical Protocols, Diabetes Mellitus, Type 1, Female, Gastric Emptying, Humans, Male, Middle Aged, Pyloric Antrum, Ultrasonography, Reproducibility of Results, Body Mass Index, Gastroparesis, Statistics, Nonparametric

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review