Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Scintigraphic measurement of gastric emptying and ultrasonographic assessment of antral area: relation to appetite.

Open access
Hveem, K, Jones, K L, Chatterton, B E, Horowitz, M · 1996 · Gut

Abstract

BACKGROUND: Ultrasound measurement of gastric emptying has potential advantages over scintigraphy, but there is little information about its accuracy. AIMS: The relation between ultrasonographic measurements of antral area and (a) scintigraphic measurements of gastric emptying and intragastric distribution of liquids (b) postprandial satiation, were evaluated. SUBJECTS: Seven normal volunteers were studied. METHOD: Each subject drank 75 g dextrose dissolved in 350 ml of water (300 kcal) or beef soup (20 kcal), both labelled with technetium-99m sulphur colloid on separate days and had measurement of gastric emptying by scintigraphy and ultrasound. RESULTS: Scintigraphic and ultrasound 50% emptying times (T50s) were comparable and longer (p < 0.001) for dextrose than soup mean (SEM) (dextrose 107 (16) min v 108 (18) min, soup 24 (4) min v 23 (5) min). There were close correlations between scintigraphic and ultrasound T50s (dextrose r = 0.94, p < 0.005, soup r = 0.97, p < 0.001) and between the time at which the distal stomach content decreased from its maximum value by 50% (measured scintigraphically) and the ultrasound T50 (dextrose r = 0.95, p < 0.005, soup r = 0.99, p < 0.0001). In contrast, there was no significant relation between the distal stomach content when expressed as a percentage of the maximum content in the total stomach and the ultrasound T50. After dextrose, fullness was related (r = 0.92, p < 0.01) to the postprandial increase in antral area measured by ultrasound. CONCLUSIONS: Ultrasound measurements of gastric emptying are: (a) of comparable sensitivity to scintigraphy in quantifying emptying of both low and high nutrient liquids (b) correlate with postprandial satiation, suggesting that the latter may be mediated by antral distension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.38.6.816

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 180

Metadata

Authors
Hveem, K., Jones, K. L., Chatterton, B. E., & Horowitz, M.
Venue
Gut
Publisher
BMJ
Published
1996-06
Volume
38
Issue
6
Pages
816-821
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2029952265
Cited by
180
References
3
FWCI
4.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Scintigraphic measurement of gastric emptying and ultrasonographic assessment of antral area: relation to appetite. https://app.cochat.ai/papers/10.1136/gut.38.6.816
The paper
Hveem, K., Jones, K. L., Chatterton, B. E., & Horowitz, M. (1996). Scintigraphic measurement of gastric emptying and ultrasonographic assessment of antral area: relation to appetite. Gut. https://doi.org/10.1136/gut.38.6.816

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.