Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diagnostic accuracy study of anorectal manometry for diagnosis of dyssynergic defecation

Open access
Grossi, Ugo, Carrington, Emma V, Bharucha, Adil E, Horrocks, Emma J, Scott, S Mark, Knowles, Charles H·2016·Gut

Abstract

Objective: The diagnostic accuracy of anorectal manometry (AM), which is necessary to diagnose functional defecatory disorders (FDD), is unknown. Using blinded analysis and standardised reporting of diagnostic accuracy, we evaluated whether AM could discriminate between asymptomatic controls and patients with functional constipation (FC). Design: Derived line plots of anorectal pressure profiles during simulated defecation were independently analysed in random order by three expert observers blinded to health status in 85 women with FC and 85 age-matched asymptomatic healthy volunteers (HV). Using accepted criteria, these pressure profiles were characterised as normal (ie, increased rectal pressure coordinated with anal relaxation) or types I–IV dyssynergia. Interobserver agreement and diagnostic accuracy were determined. Results: Blinded consensus-based assessment disclosed a normal pattern in 16/170 (9%) of all participants and only 11/85 (13%) HV. The combined frequency of dyssynergic patterns (I–IV) was very similar in FC (80/85 (94%)) and HV (74/85 (87%)). Type I dyssynergia (‘paradoxical’ contraction) was less prevalent in FC (17/85 (20%) than in HV (31/85 (36.5%), p=0.03). After statistical correction, only type IV dyssynergia was moderately useful for discriminating between FC (39/85 (46%)) and HV (17/85 (20%)) (p=0.001, positive predictive value=70.0%, positive likelihood ratio=2.3). Interobserver agreement was substantial or moderate for identifying a normal pattern, dyssynergia types I and IV, and FDD, and fair for types II and III. Conclusions: While the interpretation of AM patterns is reproducible, nearly 90% of HV have a pattern that is currently regarded as ‘abnormal’ by AM. Hence, AM is of limited utility for distinguishing between FC and HV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gutjnl-2014-308835

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 205

Metadata

Authors
Grossi, U., Carrington, E. V., Bharucha, A. E., Horrocks, E. J., Scott, S. M., & Knowles, C. H.
Venue
Gut
Publisher
BMJ
Published
2015-03-12
Volume
65
Issue
3
Pages
447-455
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2134937711
Cited by
205
References
1
FWCI
15.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy study of anorectal manometry for diagnosis of dyssynergic defecation. https://app.cochat.ai/papers/10.1136/gutjnl-2014-308835
The paper
Grossi, U., Carrington, E. V., Bharucha, A. E., Horrocks, E. J., Scott, S. M., & Knowles, C. H. (2016). Diagnostic accuracy study of anorectal manometry for diagnosis of dyssynergic defecation. Gut. https://doi.org/10.1136/gutjnl-2014-308835

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.