The DOI matches its Crossref record.
Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries
Open accessAbstract
OBJECTIVE: To improve the biocompatibility of stents using a phosphorylcholine coated stent as a form of biomimicry. INTERVENTIONS: Implantation of phosphorylcholine coated (n = 20) and non-coated (n = 21) stents was performed in the coronary arteries of 25 pigs. The animals were killed after five days (n = 6), four weeks (n = 7), and 12 weeks (n = 8), and the vessels harvested for histology, scanning electron microscopy, and morphometry. MAIN OUTCOME MEASURES: Stent performance was assessed by studying early endothelialisation, neointima formation, and vessel wall reaction to the synthetic coating. RESULTS: Stent thrombosis did not occur in either group. Morphometry showed no significant differences between the two study groups at any time point. At five days both the coated and non-coated stents were equally well endothelialised (91% v 92%, respectively). At four and 12 weeks there was no difference in intimal thickness between the coated and non-coated stents. Up to 12 weeks postimplant the phosphorylcholine coating was still discernible in the stent strut voids, and did not appear to elicit an adverse inflammatory response. CONCLUSION: In this animal model the phosphorylcholine coating showed excellent blood and tissue compatibility, unlike a number of other polymers tested in a similar setting. Given that the coating was present up to 12 weeks postimplant with no adverse tissue reaction, it may be a potential candidate polymer for local drug delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Fajadet, J., Wijns, W., Laarman, G.-J., Kuck, K.-H., Ormiston, J., Münzel, T., Popma, J. J., Fitzgerald, P. J., Bonan, R., & Kuntz, R. E. (2006) · Circulation · doi:10.1161/circulationaha.105.591206 · Cited by 464
Development of a polymer stent with shape memory effect as a drug delivery system
Wache, H. M., Tartakowska, D. J., Hentrich, A., & Wagner, M. H. (2003) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1022007510352 · Cited by 285
Novel thromboresistant materials
Jordan, S. W., & Chaikof, E. L. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.02.048 · Cited by 153
Tateishi, K., Saito, Y., Kitahara, H., & Kobayashi, Y. (2022) · Journal of Cardiology · doi:10.1016/j.jjcc.2021.08.009 · Cited by 16
Metadata
- Authors
- Whelan, D. M., van der Giessen, W. J., Krabbendam, S. C., van Vliet, E. A., Verdouw, P. D., Serruys, P. W., & van Beusekom, H. M. M.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2000-03-01
- Volume
- 83
- Issue
- 3
- Pages
- 338-345
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2110347218
- Cited by
- 221
- References
- 0
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries. https://app.cochat.ai/papers/10.1136/heart.83.3.338
- The paper
- Whelan, D. M., van der Giessen, W. J., Krabbendam, S. C., van Vliet, E. A., Verdouw, P. D., Serruys, P. W., & van Beusekom, H. M. M. (2000). Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries. Heart. https://doi.org/10.1136/heart.83.3.338
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.