Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 303

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

The “no-reflow” phenomenon: basic science and clinical correlates

Open access
Reffelmann, Thorsten, Kloner, Robert A · 2002 · Heart

Abstract

o achieve early and complete reperfusion of the myocardium in acute coronary syndromes is the daily challenge for every physician in clinical cardiology.However, restoration of epicardial blood flow by thrombolysis, primary angioplasty or bypass surgery does not necessarily imply complete reperfusion, even if the target stenosis is adequately removed or bypassed.The amount of microvascular integrity may limit reperfusion to the previously ischaemic tissue despite complete restoration of epicardial vessel diameters.A 74 year old man with acute distress is admitted to the emergency room because of acute onset of severe, substernal, crushing chest pain two hours ago.He has never suffered from similar symptoms before.The ECG shows ST segment elevation in leads I, aVL, V2-V4.After aspirin and heparin, the patient is immediately transferred to the catheterisation laboratory.Coronary angiography confirms a thrombotic occlusion of the proximal left anterior descending artery.The guide wire easily crosses the occlusion.After coronary artery balloon dilatation and stent implantation the epicardial artery appears to have gained sufficient luminal diameter.However, the contrast medium is only slowly conveyed to the distal artery and not adequately washed out.Even the final angiogram after glyceryl trinitrate in different projections shows no satisfactory flow albeit no visible flow limiting obstacles, such as coronary artery dissection or recurrent thrombus formation.The battle, undertaken to restore myocardial blood supply, seems to be lost and won, finally leading to compromised tissue perfusion despite a successful restoration of patency to the epicardial blood vessel.A bolus of abciximab, followed by a continuous infusion, is initiated.ST segment elevations resolve only slightly during the next hours; the patient requires prolonged intensive medical care because of recurrent pulmonary oedema.Finally, the patient is stabilised on cardiovascular medication including an angiotensin converting enzyme (ACE) inhibitor, oxygen, and aspirin.The echocardiography shows a large akinetic segment of the anteroseptal wall with an apical aneurysm, and a global ejection fraction of 30%.Angiographic no-reflow, as described above, may be one of the clinically most obvious manifestations of microvascular damage.The following discussion will set forward that the so-called "noreflow" phenomenon is far more frequent, and has important prognostic implications.Combining results from basic science and clinical research, we try to elucidate major mechanisms of no-reflow, methods of assessing microvascular dysfunction, and its significance in the clinical setting. c WHAT IS KNOWN ABOUT NO-REFLOW FROM ANIMAL STUDIES? Anatomical no-reflowIn experimental models of myocardial infarction, injection of various dyes to the circulation has been traditionally used to stain perfused tissue.As shown in fig 1, a substantial part of the myocardium, after being subjected to proximal coronary occlusion and reperfusion of the epicardial artery, may remain unstained after injection of monastral blue or thioflavin S (a fluorescent vital stain for endothelium).The resulting visual perfusion defects represent the so-called "anatomical" no-reflow.Systematic investigations in the canine model of myocardial infarction demonstrated a homogenous distribution of thioflavin S after 40 minutes of ischaemia with subsequent reperfusion.However, after 90 minutes, areas of no-reflow were identified as zones not stained by the fluorescent dye, 1 indicating that a certain duration of ischaemia is necessary for the development of no-reflow.In the canine model, these zones of no-reflow first appeared in the subendocardium. Ultrastructural changesElectron microscopy of these areas of no-reflow revealed swollen intraluminal endothelial protrusions and membrane bound intraluminal bodies, which appeared to be free floating and often seemed to obstruct the capillary lumen.Endothelial cells showed decreased numbers of pinocytotic vesicles and nuclear chromatin margination.After 20 minutes of reperfusion, capillaries contained tightly packed erythrocytes, endothelial gaps, sometimes plugged by platelet and fibrin thrombi, with numerous extravascular red blood cells.Occasionally, capillaries seemed to be compressed by

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heart.87.2.162

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 303

Metadata

Authors
Reffelmann, T., & Kloner, R. A.
Venue
Heart
Publisher
BMJ
Published
2002-02
Volume
87
Issue
2
Pages
162-168
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2051030085
Cited by
303
References
19
FWCI
7.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The “no-reflow” phenomenon: basic science and clinical correlates. https://app.cochat.ai/papers/10.1136/heart.87.2.162
The paper
Reffelmann, T., & Kloner, R. A. (2002). The “no-reflow” phenomenon: basic science and clinical correlates. Heart. https://doi.org/10.1136/heart.87.2.162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.