The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status
Open accessAbstract
Background: ‘Silent’ cerebral infarction and stroke are complications of transcatheter aortic valve implantation (TAVI). Objective: To assess the occurrence of cerebral infarction, identify predictive risk factors and examine the impact on patient health-related quality of life (HRQoL). Methods: Cerebral diffusion weighted MRI of 31 patients with aortic stenosis undergoing CoreValve TAVI was carried out. HRQoL was assessed at baseline and at 30 days by SF-12v2 and EQ5D questionnaires. Results: New cerebral infarcts occurred in 24/31 patients (77%) and stroke in 2 (6%). Stroke was associated with a greater number and volume of cerebral infarcts. Age (r=0.37, p=0.042), severity of atheroma (arch and descending aorta; r=0.91, p<0.001, r=0.69, p=0.001, respectively) and catheterisation time (r=0.45, p=0.02) were predictors of the number of new cerebral infarcts. HRQoL improved overall: SF-12v2 physical component summary increased significantly (32.4±6.2 vs 36.5±7.2; p=0.03) with no significant change in mental component summary (43.5±11.7 vs 43.1±14.3; p=0.85). The EQ5D score and Visual Analogue Scale showed no significant change (0.56±0.26 vs 0.59±0.31; p=0.70, and 54.2±19 vs 58.2±24; p=0.43). Conclusion: Multiple small cerebral infarcts occurred in 77% of patients with TAVI. The majority of infarcts were ‘silent’ with clinical stroke being associated with a both higher infarct number and volume. Increased age and the severity of aortic arch atheroma were independent risk factors for the development of new cerebral infarcts. Overall HRQoL improved and there was no association between the number of new cerebral infarcts and altered health status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WARE, J. E., KOSINSKI, M., & KELLER, S. D. (1996) · Medical Care · doi:10.1097/00005650-199603000-00003 · Cited by 17,392
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery?
Iung, B., Cachier, A., Baron, G., Messika-Zeitoun, D., Delahaye, F., Tornos, P., Gohlke-Bärwolf, C., Boersma, E., Ravaud, P., & Vahanian, A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi471 · Cited by 1,108
Yoshitake, T., Kiyohara, Y., Kato, I., Ohmura, T., Iwamoto, H., Nakayama, K., Ohmori, S., Nomiyama, K., Kawano, H., Ueda, K., et al. (1995) · Neurology · doi:10.1212/wnl.45.6.1161 · Cited by 829
Cited by
Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement
Kapadia, S. R., Kodali, S., Makkar, R., Mehran, R., Lazar, R. M., Zivadinov, R., Dwyer, M. G., Jilaihawi, H., Virmani, R., Anwaruddin, S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.023 · Cited by 509
Eggebrecht, H., Schmermund, A., Voigtländer, T., Kahlert, P., Erbel, R., & Mehta, R. H. (2012) · EuroIntervention · doi:10.4244/eijv8i1a20 · Cited by 406
Haussig, S., Mangner, N., Dwyer, M. G., Lehmkuhl, L., Lücke, C., Woitek, F., Holzhey, D. M., Mohr, F. W., Gutberlet, M., Zivadinov, R., et al. (2016) · JAMA · doi:10.1001/jama.2016.10302 · Cited by 367
Lansky, A. J., Schofer, J., Tchetche, D., Stella, P., Pietras, C. G., Parise, H., Abrams, K., Forrest, J. K., Cleman, M., Reinöhl, J., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv191 · Cited by 308
Self-citationNeurocognitive Function after Cardiac Surgery: From Phenotypes to Mechanisms
Berger, M., Terrando, N., Smith, S. K., Browndyke, J. N., Newman, M. F., & Mathew, J. P. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002194 · Cited by 256
Metadata
- Authors
- Fairbairn, T. A., Mather, A. N., Bijsterveld, P., Worthy, G., Currie, S., Goddard, A. J. P., Blackman, D. J., Plein, S., & Greenwood, J. P.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2011-07-07
- Volume
- 98
- Issue
- 1
- Pages
- 18-23
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2150873438
- Cited by
- 177
- References
- 4
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status. https://app.cochat.ai/papers/10.1136/heartjnl-2011-300065
- The paper
- Fairbairn, T. A., Mather, A. N., Bijsterveld, P., Worthy, G., Currie, S., Goddard, A. J. P., Blackman, D. J., Plein, S., & Greenwood, J. P. (2012). Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status. Heart. https://doi.org/10.1136/heartjnl-2011-300065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.