CoChat

Prognosis of the bradycardia pacemaker recipient assessed at first implantation: a nationwide cohort study

Udo, Erik O, van Hemel, Norbert M, Zuithoff, Nicolaas P A, Doevendans, Pieter A, Moons, Karel G M · 2013 · Heart
Cited by 33

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Pacing technology and care have improved notably over the past decade, justifying an update on the long-term prognosis and pre-implantation determinants of prognosis of bradycardia pacemaker (PM) recipients. DESIGN: Prospective cohort study. SETTING: 23 Dutch pacemaker centres PATIENTS: Pre-implantation characteristics of 1517 patients receiving a first bradycardia PM between 2003-2007 were studied in relation to survival. INTERVENTIONS: None; patients were followed up during routine clinical practice. MAIN OUTCOME MEASURES: Cause and time to death. RESULTS: At the end of a mean follow-up of 5.8 (SD 1.1) years, 512 patients (33%) died, mostly of non-cardiac cause (67%). There were two PM related deaths. Survival rates were 93%, 81%, 69%, and 61% after 1, 3, 5 and 7 years, respectively. PM recipients without concomitant cardiovascular disease at implantation showed survival rates comparable to age and sex matched controls. Predictors at time of implantation associated with cardiac mortality were: age, coronary artery disease (CAD), diabetes, heart failure, valve disease, and the indication for PM implantation. Predictors for all cause mortality were: male gender, age, body mass index, CAD, cardiac surgery, diabetes, heart failure, and maintained atrioventricular synchrony. CONCLUSIONS: A pre-implantation history of heart failure, CAD, and diabetes are the most important predictors for worse prognosis in PM recipients. Without baseline heart disease, survival rates equal that of the general population, suggesting that the prognosis of contemporary PM recipients is mainly determined by comorbid diseases and a bradycardia pacing indication as such does not influence survival. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00135174.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heartjnl-2013-304445

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 33

Metadata

Authors
Udo, E. O., van Hemel, N. M., Zuithoff, N. P. A., Doevendans, P. A., & Moons, K. G. M.
Venue
Heart
Publisher
BMJ
Published
2013-08-22
Volume
99
Issue
21
Pages
1573-1578
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2167518638
Cited by
33
References
5
FWCI
1.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognosis of the bradycardia pacemaker recipient assessed at first implantation: a nationwide cohort study. https://app.cochat.ai/papers/10.1136/heartjnl-2013-304445
The paper
Udo, E. O., van Hemel, N. M., Zuithoff, N. P. A., Doevendans, P. A., & Moons, K. G. M. (2013). Prognosis of the bradycardia pacemaker recipient assessed at first implantation: a nationwide cohort study. Heart. https://doi.org/10.1136/heartjnl-2013-304445

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.