Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Although the presence of an RV lead is a potential cause of tricuspid regurgitation (TR), the clinical impact of significant lead-induced TR is unknown. Objective: To evaluate the effect of significant lead-induced TR on cardiac performance and long-term outcome after cardioverter-defibrillator (ICD) or pacemaker implantation. Methods: A retrospective cohort of 239 ICD (n=191) or pacemaker (n=48) recipients (age 60±14 years, 77% male) from a tertiary care university hospital, with an echocardiographic evaluation before and within 1–1.5 years after device implantation were included. Significant lead-induced TR was defined as TR worsening, reaching a grade ≥2 at follow-up echocardiography. During long-term follow-up (median 58, IQR 35–76 months), all-cause mortality and heart failure related events were recorded. Results: Before device implantation, most patients had TR grade 1 or 2 (64.0%) or no TR (33.9%), but after lead placement, significant TR was seen in 91 patients (38%). Changes in cardiac volumes and function at follow-up were similar between patients with and without significant lead-induced TR, except for larger RV diastolic area (17±6mm 2 vs 16±5mm 2, p=0.009), larger right atrial diameter (39±10 mm vs 36±8 mm, p<0.001) and higher pulmonary arterial pressures (41±15 mm Hg vs 33±10 mm Hg, p<0.001) in patients with significant lead-induced TR. Patients with significant lead-induced TR had worse long-term survival (HR=1.687, p=0.040) and/or more heart failure related events (HR=1.641, p=0.019). At multivariate analysis, significant lead-induced TR was independently associated with all-cause mortality (HR=1.749, p=0.047) together with age, LVEF and percentage RV pacing. Conclusions: Significant lead-induced TR is associated with poor long-term prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Authors/Task Force Members, Galie, N., Hoeper, M. M., Humbert, M., Torbicki, A., Vachiery, J.-L., Barbera, J. A., Beghetti, M., Corris, P., Gaine, S., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp297 · Cited by 3,846
Self-citationRecommendations for chamber quantification☆
LANG, R., BIERIG, M., DEVEREUX, R., FLACHSKAMPF, F., FOSTER, E., PELLIKKA, P., PICARD, M., ROMAN, M., SEWARD, J., & SHANEWISE, J. (2006) · European Journal of Echocardiography · doi:10.1016/j.euje.2005.12.014 · Cited by 3,571
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Impact of tricuspid regurgitation on long-term survival
Nath, J., Foster, E., & Heidenreich, P. A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.036 · Cited by 1,677
Lancellotti, P., Moura, L., Pierard, L. A., Agricola, E., Popescu, B. A., Tribouilloy, C., Hagendorff, A., Monin, J. L., Badano, L., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq031 · Cited by 1,545
Singh, J. P., Evans, J. C., Levy, D., Larson, M. G., Freed, L. A., Fuller, D. L., Lehman, B., & Benjamin, E. J. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)01064-9 · Cited by 1,339
Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., Leon, A., Yee, R., Marinchak, R. A., Flaker, G., Schron, E., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 997
Cited by
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citation2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citation2021 ESC/EACTS Guidelines for the management of valvular heart disease
Beyersdorf, F., Vahanian, A., Milojevic, M., Praz, F., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2021) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezab389 · Cited by 622
Self-citation2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · EuroIntervention · doi:10.4244/eij-e-21-00009 · Cited by 372
Self-citationThe modern epidemiology of heart valve disease
Coffey, S., Cairns, B. J., & Iung, B. (2016) · Heart · doi:10.1136/heartjnl-2014-307020 · Cited by 321
Transcatheter treatment for tricuspid valve disease
Praz, F., Muraru, D., Kreidel, F., Lurz, P., Hahn, R. T., Delgado, V., Senni, M., von Bardeleben, R. S., Nickenig, G., Hausleiter, J., et al. (2021) · EuroIntervention · doi:10.4244/eij-d-21-00695 · Cited by 313
Self-citationHahn, R. T., Badano, L. P., Bartko, P. E., Muraru, D., Maisano, F., Zamorano, J. L., & Donal, E. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeac009 · Cited by 266
Transcatheter treatment for tricuspid valve disease.
Praz, F., Muraru, D., Kreidel, F., Lurz, P. C., Hahn, R. T., Delgado, V., Senni, M., von Bardeleben, R. S., Nickenig, G., Hausleiter, J., et al. (2021) · doi:10.48350/163244 · Cited by 265
Self-citationMorphologic Types of Tricuspid Regurgitation
Prihadi, E. A., Delgado, V., Leon, M. B., Enriquez-Sarano, M., Topilsky, Y., & Bax, J. J. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.09.027 · Cited by 249
“5 years after lead insertion (Figure 1) (4).”
BackgroundSelf-citationTricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation
Chang, J. D., Manning, W. J., Ebrille, E., & Zimetbaum, P. J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.055 · Cited by 238
“In a comparison of 2D and 3D TTE for the diagnosis of lead-related TR in 87 patients with CIEDs, it was found that 2D TTE satisfactorily delineated the spatial relationship between lead and valve in only 17.2% of patients, whereas 3D TTE did so in 94.2% (41).”
BackgroundInfluentialIsolated tricuspid regurgitation: outcomes and therapeutic interventions
Fender, E. A., Zack, C. J., & Nishimura, R. A. (2018) · Heart · doi:10.1136/heartjnl-2017-311586 · Cited by 221
Prihadi, E. A., van der Bijl, P., Gursoy, E., Abou, R., Mara Vollema, E., Hahn, R. T., Stone, G. W., Leon, M. B., Ajmone Marsan, N., Delgado, V., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy352 · Cited by 209
Self-citationTransfemoral Transcatheter Tricuspid Valve Replacement With the EVOQUE System
Fam, N. P., von Bardeleben, R. S., Hensey, M., Kodali, S. K., Smith, R. L., Hausleiter, J., Ong, G., Boone, R., Ruf, T., George, I., et al. (2021) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.11.045 · Cited by 196
Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation
Addetia, K., Harb, S. C., Hahn, R. T., Kapadia, S., & Lang, R. M. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.09.028 · Cited by 190
“(11) did not find any significant differences between patients who developed lead-related TR and those who did not.”
BackgroundResultInfluentialTricuspid Regurgitation and Mortality in Patients With Transvenous Permanent Pacemaker Leads
Delling, F. N., Hassan, Z. K., Piatkowski, G., Tsao, C. W., Rajabali, A., Markson, L. J., Zimetbaum, P. J., Manning, W. J., Chang, J. D., & Mukamal, K. J. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.12.038 · Cited by 159
Metadata
- Authors
- Höke, U., Auger, D., Thijssen, J., Wolterbeek, R., van der Velde, E. T., Holman, E. R., Schalij, M. J., Bax, J. J., Delgado, V., & Marsan, N. A.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2014-01-21
- Volume
- 100
- Issue
- 12
- Pages
- 960-968
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2138488319
- Cited by
- 215
- References
- 24
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.