Bioprosthetic aortic valve durability in the era of transcatheter aortic valve implantation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The main limitation of bioprosthetic valves is their limited durability, which exposes the patient to the risk of aortic valve reintervention. Transcatheter aortic valve implantation (TAVI) is considered a reasonable alternative to surgical aortic valve replacement (SAVR) in patients with intermediate or high surgical risk. TAVI is now rapidly expanding towards the lower risk populations. Although the results of midterm durability of the transcatheter bioprostheses are encouraging, their long-term durability remains largely unknown. The objective of this review article is to present the definition, mechanisms, incidence, outcome and management of structural valve deterioration of aortic bioprostheses with specific emphasis on TAVI. The structural valve deterioration can be categorised into three stages: stage 1: morphological abnormalities (fibrocalcific remodelling and tear) of bioprosthesis valve leaflets without hemodynamic valve deterioration; stage 2: morphological abnormalities and moderate hemodynamic deterioration (increase in gradient and/or new onset of transvalvular regurgitation); and stage 3: morphological abnormalities and severe hemodynamic deterioration. Several specifics inherent to the TAVI including valve oversizing, manipulation, delivery, positioning and deployment may cause injuries to the valve leaflets and increase leaflet mechanical stress, which may limit the long-term durability of transcatheter bioprostheses. The selection of the type of aortic valve replacement and bioprosthesis should thus take into account the ratio between the demonstrated durability of the bioprostheses versus the life expectancy of the patient. Pending the publication of robust data on long-term durability of transcatheter bioprostheses, it appears reasonable to select SAVR with a bioprosthesis model that has well-established long-term durability in patients with low surgical risk and long life expectancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Brown, J. M., O'Brien, S. M., Wu, C., Sikora, J. A. H., Griffith, B. P., & Gammie, J. S. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.08.015 · Cited by 937
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
Self-citationKapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60290-2 · Cited by 867
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
2020 ACC/AHA guideline for the management of patients with valvular heart disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2021.04.002 · Cited by 279
Pibarot, P., Ternacle, J., Jaber, W. A., Salaun, E., Dahou, A., Asch, F. M., Weissman, N. J., Rodriguez, L., Xu, K., Annabi, M.-S., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.049 · Cited by 217
“Women have smaller aortic annuli and are at higher risk for severe prosthesis-patient mismatch and high residual gradient following valve replacement, which may predispose to accelerated SVD (13,23,37).”
BackgroundSelf-citationWang, X., Liu, J., Jing, H., Li, B., Sun, Z., Li, B., Kong, D., Leng, X., & Wang, Z. (2021) · Materials Science and Engineering: C · doi:10.1016/j.msec.2021.111872 · Cited by 25
Metadata
- Authors
- Salaun, E., Clavel, M.-A., Rodés-Cabau, J., & Pibarot, P.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2018-05-07
- Volume
- 104
- Issue
- 16
- Pages
- 1323-1332
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2803009092
- Cited by
- 106
- References
- 4
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.