Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 284

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Association of increased carotid intima-media thickness with the extent of coronary artery disease

Open access
Kablak-Ziembicka, A, Tracz, W, Przewlocki, T, Pieniazek, P, Sokolowski, A, Konieczynska, M · 2004 · Heart

Abstract

Objective: To investigate (a) the relation between intima-media thickness (IMT) in carotid arteries and the extent of coronary artery disease (CAD); and (b) whether IMT is predictive of coronary atherosclerosis. The coexistence of severe extracranial atherosclerosis in patients with CAD was also analysed. Methods: Coronary angiography and carotid ultrasound evaluation were performed in 558 consecutive patients (438 men), with a mean (SD) age of 58.8 (9.2) years and suspected CAD. Mean IMT was measured at both carotid arteries and expressed as the mean aggregate value. The relation between IMT and severity of CAD was determined. Results: A significant correlation between mean IMT and advancing CAD (p < 0.0001) was found. Four independent predictors of CAD were found in the discriminant analysis: age (p = 0.0193), hyperlipidaemia (p < 0.0001), smoking (p = 0.0032), and IMT (p < 0.0001). A significant increase in IMT was observed among patients with one, two, and three vessel CAD. A log normal distribution of IMT values showed that if mean IMT was over 1.15 mm, patients had a 94% probability of having CAD, with sensitivity of 65% and specificity of 80% in the patients with a high risk of CAD. The number of critically stenosed extracranial arteries increased with advancing CAD. None of the patients with normal coronary arteries had severe stenosis of the extracranial arteries. Severe carotid, vertebral, or subclavian stenosis was found in 16.6% of patients with three vessel CAD. Conclusions: IMT increases with advancing CAD, patients with mean IMT over 1.15 mm have a 94% likelihood of having CAD, and the coexistence of CAD with severe stenosis of aortic arch arteries is relatively high and was found in 16.6% of patients with three vessel CAD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.2003.025080

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 284

Metadata

Authors
Kablak-Ziembicka, A., Tracz, W., Przewlocki, T., Pieniazek, P., Sokolowski, A., & Konieczynska, M.
Venue
Heart
Publisher
BMJ
Published
2004-10-14
Volume
90
Issue
11
Pages
1286-1290
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2110930964
Cited by
284
References
24
FWCI
8.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association of increased carotid intima-media thickness with the extent of coronary artery disease. https://app.cochat.ai/papers/10.1136/hrt.2003.025080
The paper
Kablak-Ziembicka, A., Tracz, W., Przewlocki, T., Pieniazek, P., Sokolowski, A., & Konieczynska, M. (2004). Association of increased carotid intima-media thickness with the extent of coronary artery disease. Heart. https://doi.org/10.1136/hrt.2003.025080

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.