Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Diagnostic accuracy of B type natriuretic peptide and amino terminal proBNP in the emergency diagnosis of heart failure

Open access
Mueller, T·2005·Heart

Abstract

OBJECTIVE: To compare head to head the diagnostic accuracy of B type natriuretic peptide (BNP) and the amino terminal fragment of its precursor hormone (NT-proBNP) for congestive heart failure (CHF) in an emergency setting. METHODS: 251 consecutive patients presenting to the emergency department with dyspnoea as a chief complaint were prospectively studied. Patients with acute coronary syndromes were excluded. The diagnosis of CHF was based on the Framingham score for CHF plus echocardiographic evidence of systolic or diastolic dysfunction. Blood concentrations of BNP and NT-proBNP were measured by two commercially available assays (Abbott and Roche methods). The diagnostic accuracies of BNP and NT-proBNP were assessed by receiver operating characteristic curve analysis. RESULTS: Areas under the curve for BNP and NT-proBNP in patients with dyspnoea caused by CHF (n = 137) and in patients with dyspnoea attributable to other reasons (n = 114) did not differ significantly (area under the curve 0.916 v 0.903, p = 0.277, statistical power 94%). Cut off concentrations with the highest diagnostic accuracy were 295 ng/l for BNP (sensitivity 80%, specificity 86%, diagnostic accuracy 83%) and 825 ng/l for NT-proBNP (sensitivity 87%, specificity 81%, diagnostic accuracy 84%). Evaluation of discordant false classifications at these cut off concentrations showed no advantage for either BNP nor NT-proBNP in the biochemical diagnosis of CHF (17 misclassifications by BNP and 14 by NT-proBNP, p = 0.720). In the population studied, age, sex, and renal function had no impact on the diagnostic utility of both tests when compared by logistic regression models. CONCLUSIONS: BNP and NT-proBNP may be equally useful as an aid in the diagnosis of CHF in short of breath patients presenting to the emergency department.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.2004.037762

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 205

Metadata

Authors
Mueller, T.
Venue
Heart
Publisher
BMJ
Published
2005-05-01
Volume
91
Issue
5
Pages
606-612
ISSN
1355-6037 (ISSN-L)
OpenAlex
W1985982734
Cited by
205
References
3
FWCI
16.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of B type natriuretic peptide and amino terminal proBNP in the emergency diagnosis of heart failure. https://app.cochat.ai/papers/10.1136/hrt.2004.037762
The paper
Mueller, T. (2005). Diagnostic accuracy of B type natriuretic peptide and amino terminal proBNP in the emergency diagnosis of heart failure. Heart. https://doi.org/10.1136/hrt.2004.037762

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.