The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
The long-term survival and the risks and benefits of implantable cardioverter defibrillators in patients with hypertrophic cardiomyopathy
Abstract
Objective: Implantable cardioverter defibrillators (ICDs) are routinely used to prevent sudden cardiac death (SCD) in selected hypertrophic cardiomyopathy (HCM) patients, but the determinants of device-related complications, therapies and long-term cardiovascular mortality in ICD recipients are not known. Design: Retrospective observational cohort study. Setting: Single-centre tertiary referral cardiomyopathy clinic. Patients: 334 consecutively evaluated HCM patients (median age 40 years, 62% male, 92% primary prevention) at risk of SCD treated with ICD. Thirty-six patients (11%) received concurrent cardiac resynchronisation therapy for heart failure symptoms. Results: During the 1286 patient-years of follow-up, cardiovascular mortality (including transplantation) occurred in 22 (7%) patients (1.7%/year) and was associated with New York Heart Association (NYHA) class III/IV (adjusted HR=9.38, 95% CI 3.31 to 26.55, p≤0.001), percentage fractional shortening (HR=0.92, 95% CI 0.87 to 0.96, p=0.001) and implantation for secondary prevention (HR=0.07, 95% CI 0.01 to 0.86, p=0.04). There were no SCD. Twenty-eight (8%) patients received appropriate shocks (2.3%/year), which were predicted by baseline fractional shortening (HR=0.96, 95% CI 0.92 to 0.99, p=0.04). Fifty-five (16%) patients received inappropriate shocks (4.6%/year). Sixty (18%) patients experienced implant-related complications (5.1%/year), including two deaths. Adverse ICD-related events (inappropriate shocks and/or implant complications) were seen in 101 (30%) patients (8.6%/year). Patients with cardiac resynchronisation therapy were more likely to develop implant complications than those with single-chamber ICDs (HR=4.39, 95% CI 1.44 to 13.35, p=0.009) and had a higher 5-year cardiovascular mortality than did the rest of the cohort (21% vs 6%, p<0.001). Conclusions: HCM patients with an ICD have a significant cardiovascular mortality and are exposed to frequent inappropriate shocks and implant complications. These data suggest that new strategies are required to improve patient selection for ICDs and to prevent disease progression in those that receive a device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
(1996) · Circulation · doi:10.1161/01.cir.93.5.841 · Cited by 3,458
Self-citationACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Christiaans, I., van Engelen, K., van Langen, I. M., Birnie, E., Bonsel, G. J., Elliott, P. M., & Wilde, A. A. M. (2010) · EP Europace · doi:10.1093/europace/eup431 · Cited by 176
Cited by
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Self-citationPriori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citation2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
Self-citationAl-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,854
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Metadata
- Authors
- O'Mahony, C., Lambiase, P. D., Quarta, G., Cardona, M., Calcagnino, M., Tsovolas, K., Al-Shaikh, S., Rahman, S. M., Arnous, S., Jones, S., McKenna, W., & Elliott, P.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2011-07-13
- Volume
- 98
- Issue
- 2
- Pages
- 116-125
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2151730996
- Cited by
- 179
- References
- 4
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The long-term survival and the risks and benefits of implantable cardioverter defibrillators in patients with hypertrophic cardiomyopathy. https://app.cochat.ai/papers/10.1136/hrt.2010.217182
- The paper
- O'Mahony, C., Lambiase, P. D., Quarta, G., Cardona, M., Calcagnino, M., Tsovolas, K., Al-Shaikh, S., Rahman, S. M., Arnous, S., Jones, S., McKenna, W., & Elliott, P. (2012). The long-term survival and the risks and benefits of implantable cardioverter defibrillators in patients with hypertrophic cardiomyopathy. Heart. https://doi.org/10.1136/hrt.2010.217182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.