The DOI matches its Crossref record.
Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound.
Open accessAbstract
A noninvasive method is described for measuring the pressure drop across the mitral valve in mitral stensois by Doppler ultrasound. A maximum frequency estimator was used to record maximum velocity in the Doppler signal from the mitral jet. Provided the angle between the ultrasound beam and the maximum velocity is close to zero the pressure drop can be calculated directly. Good correlation was found between Doppler measurements and simultaneous pressure recordings during heart catheterisation in 10 patients. No false negative or false positive diagnoses of mitral stenosis were made among 55 patients (35 patients with mitral stenosis and 20 patients with other valve lesions). The measurements were easy to perform in most patients and the method seems well suited both to diagnose and to follow patients with mitral stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O'Gara, P. T., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.007 · Cited by 2,257
Quiñones, M. A., Otto, C. M., Stoddard, M., Waggoner, A., & Zoghbi, W. A. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.120202 · Cited by 2,130
ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.021 · Cited by 1,702
Yock, P. G., & Popp, R. L. (1984) · Circulation · doi:10.1161/01.cir.70.4.657 · Cited by 1,640
Appleton, C. P., Hatle, L. K., & Popp, R. L. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90416-0 · Cited by 1,568
Self-citationACC/AHA guidelines for the management of patients with valvular heart disease
Bonow, R., Carabello, B., de Leon, A., Edmunds, L. H., Fedderly, B., Freed, M., Gaasch, W., McKay, C., Nishimura, R., O’Gara, P., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00454-9 · Cited by 1,134
2006 WRITING COMMITTEE MEMBERS, Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190748 · Cited by 1,114
Bonow, R. O., Carabello, B., de Leon, A. C., Edmunds, L. H., Fedderly, B. J., Freed, M. D., Gaasch, W. H., McKay, C. R., Nishimura, R. A., O’Gara, P. T., et al. (1998) · Circulation · doi:10.1161/01.cir.98.18.1949 · Cited by 1,034
Berger, M., Haimowitz, A., Van Tosh, A., Berdoff, R. L., & Goldberg, E. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80172-8 · Cited by 742
Non-invasive assessment of aortic stenosis by Doppler ultrasound.
Hatle, L., Angelsen, B. A., & Tromsdal, A. (1980) · Heart · doi:10.1136/hrt.43.3.284 · Cited by 527
Self-citationGiannuzzi, P., Imparato, A., Temporelli, P. L., Vito, F. D., Silva, P. L., Scapellato, F., & Giordano, A. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90667-x · Cited by 362
Carabello, B. A., & Crawford, F. A. (1997) · New England Journal of Medicine · doi:10.1056/nejm199707033370107 · Cited by 298
Quantification of pressure gradients across stenotic valves by Doppler ultrasound
Stamm, R. B., & Martin, R. P. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80311-8 · Cited by 275
Doppler Echocardiography: Theory, Instrumentation, Technique, and Application
NISHIMURA, R. A., MILLER, F. A., CALLAHAN, M. J., BENASSI, R. C., SEWARD, J. B., & TAJIK, A. J. (1985) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)60540-0 · Cited by 263
Measurement of arterial blood flow by Doppler ultrasound
Hoskins, P. R. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/1/001 · Cited by 109
Image-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Metadata
- Authors
- Hatle, L., Brubakk, A., Tromsdal, A., & Angelsen, B.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1978-02-01
- Volume
- 40
- Issue
- 2
- Pages
- 131-140
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W2102548257
- Cited by
- 539
- References
- 0
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.