Efficacy of intravenous procainamide infusion in converting atrial fibrillation to sinus rhythm. Relation to left atrial size.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The efficacy of intravenous procainamide, infused at 30 mg/min to a maximum dose of 20 mg/kg, in converting atrial fibrillation was evaluated under electrocardiographic and blood pressure control in 21 patients. Nine patients had atherosclerotic heart disease, seven had valvular lesions, five had hypertension, and six had no apparent heart disease. Nine patients (converters), who reverted to sinus rhythm at a mean dose of procainamide of 13.3 +/- 3.6 mg/kg (mean plasma concentration, 7.4 +/- 3.9 micrograms/ml) had normal echocardiographic left atrial diameters. All but one of the remainder, the 12 non-converters, who received a mean drug dose of 13.1 +/- 3.5 mg/kg (mean plasma concentration 13.9 +/- 7.6 micrograms/ml), had atrial diameters exceeding 4.0 cm. QRS and QTc intervals were not altered significantly in converters, but were prolonged significantly in non-converters. No serious side effects from the infusion were encountered. Intravenous procainamide infusion appears to be a safe and rapidly effective method of converting recent-onset atrial fibrillation to sinus rhythm in patients with normal left atrial dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relation between echocardiographically determined left atrial size and atrial fibrillation.
Henry, W. L., Morganroth, J., Pearlman, A. S., Clark, C. E., Redwood, D. R., Itscoitz, S. B., & Epstein, S. E. (1976) · Circulation · doi:10.1161/01.cir.53.2.273 · Cited by 641
Cited by
Cheitlin, M. D., Alpert, J. S., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davidson, T. W., Davis, J. L., Douglas, P. S., Gillam, L. D., et al. (1997) · Circulation · doi:10.1161/01.cir.95.6.1686 · Cited by 831
Stambler, B. S., Wood, M. A., Ellenbogen, K. A., Perry, K. T., Wakefield, L. K., & VanderLugt, J. T. (1996) · Circulation · doi:10.1161/01.cir.94.7.1613 · Cited by 486
Ellenbogen, K. A., Stambler, B. S., Wood, M. A., Sager, P. T., Wesley, R. C., Meissner, M. D., Zoble, R. G., Wakefield, L. K., Perry, K. T., Vanderlugtt, J. T., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00121-0 · Cited by 370
Management of Atrial Fibrillation
Wood, A. J. J., & Pritchett, E. L. C. (1992) · New England Journal of Medicine · doi:10.1056/nejm199205073261906 · Cited by 325
Volgman, A. S., Carberry, P. A., Stambler, B., Lewis, W. R., Dunn, G. H., Perry, K. T., VanderLugt, J. T., & Kowey, P. R. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00078-3 · Cited by 242
Metadata
- Authors
- Halpern, S. W., Ellrodt, G., Singh, B. N., & Mandel, W. J.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1980-11-01
- Volume
- 44
- Issue
- 5
- Pages
- 589-595
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W2016659665
- Cited by
- 108
- References
- 1
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.