CoChat

Reduction of mismatch of global ventilation and perfusion on exercise is related to exercise capacity in chronic heart failure.

Open access
Uren, N G, Davies, S W, Agnew, J E, Irwin, A G, Jordan, S L, Hilson, A J, Lipkin, D P · 1993 · Heart
Cited by 58

The DOI matches its Crossref record.

Abstract

BACKGROUND: The inability to match lung perfusion to ventilation because of a reduced cardiac output on exercise contributes to reduced exercise capacity in chronic heart failure. OBJECTIVE: To quantify ventilation to perfusion matching at rest and at peak exercise in patients with chronic heart failure and relate this to haemodynamic and ventilatory variables of exercise capacity. DESIGN: Eight men in New York Heart Association class II underwent maximal bicycle ergometry with expired gas analysis. MAIN OUTCOME MEASURES: On separate days, ventilation and perfusion gamma camera imaging was performed at rest, and at 80% of previous peak exercise heart rate during bicycle ergometry. The vertical distribution of mismatch between ventilation and perfusion (V/Q) was estimated from subtracted profiles of activity (ventilation and perfusion) to derive a numerical index of global mismatch. RESULTS: Maximal mean (SD) oxygen consumption on bicycle ergometry was 16.0 (4.5) ml min-1 kg-1. There was a reduction in the global V/Q mismatch index from 23.96 (5.90) to 14.88 (7.90) units (p < 0.01) at rest and at peak exercise. Global V/Q mismatch index at peak exercise correlated negatively with maximal minute ventilation (R = -0.90, p < 0.01) and with maximal mean arterial pressure (R = -0.79, p < 0.05), although no relation was seen with maximal oxygen consumption. The reduction in global V/Q mismatch index from rest to peak exercise correlated with maximal oxygen consumption (R = 0.88, p < 0.01), and with maximal minute ventilation (R = 0.87, p < 0.01). CONCLUSIONS: During exercise in patients with chronic heart failure, there is a reduction in the global V/Q mismatch index. A lower global V/Q mismatch index at peak exercise is associated with higher maximal ventilation. The reduction in global V/Q mismatch index on exercise correlates well with maximal exercise capacity. This may imply that the inability to perfuse adequately all regions of lung on exercise and match this to ventilation is a factor determining exercise capacity in chronic heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.70.3.241

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 58

Metadata

Authors
Uren, N. G., Davies, S. W., Agnew, J. E., Irwin, A. G., Jordan, S. L., Hilson, A. J., & Lipkin, D. P.
Venue
Heart
Publisher
BMJ
Published
1993-09-01
Volume
70
Issue
3
Pages
241-246
ISSN
1355-6037 (ISSN-L)
OpenAlex
W2090139446
Cited by
58
References
0
FWCI
4.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction of mismatch of global ventilation and perfusion on exercise is related to exercise capacity in chronic heart failure. https://app.cochat.ai/papers/10.1136/hrt.70.3.241
The paper
Uren, N. G., Davies, S. W., Agnew, J. E., Irwin, A. G., Jordan, S. L., Hilson, A. J., & Lipkin, D. P. (1993). Reduction of mismatch of global ventilation and perfusion on exercise is related to exercise capacity in chronic heart failure. Heart. https://doi.org/10.1136/hrt.70.3.241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.