Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound

Open access
Ge, J, Chirillo, F, Schwedtmann, J, Görge, G, Haude, M, Baumgart, D, Shah, V, von Birgelen, C, Sack, S, Boudoulas, H, Erbel, R · 1999 · Heart

Abstract

AIM: To visualise the characteristics of ruptured plaques by intravascular ultrasound (IVUS) and to correlate plaque characteristics with clinical symptoms to establish a quantitative index of plaque vulnerability. METHODS: 144 consecutive patients with angina were examined using IVUS. Ruptured plaques, characterised by a plaque cavity and a tear on the thin fibrous cap, were identified in 31 patients (group A), of whom 23 (74%) presented with unstable angina. Plaque rupture was confirmed by injecting contrast medium filling the plaque cavity during IVUS examination. Of the patients without plaque rupture (group B, n = 108), only 19 (18%) had unstable angina. RESULTS: No significant differences were found between groups A and B in relation to plaque and vessel area (p > 0.05). Mean (SD) per cent stenosis in group A was less than in group B, at 56.2 (16.5)% v 67.9 (13.4)%; p < 0.001. Area of the emptied plaque cavity in group A (4.1 (3.2) mm 2) was larger than the echolucent zone in group B (1.32 (0.79) mm 2) (p < 0.001). The plaque cavity to plaque ratio in group A (38.5 (17.1)%) was larger than the echolucent area to plaque ratio in group B (11.2 (8.9)%) (p < 0.001). The thickness of the fibrous cap in group A was less than in group B, at 0.47 (0.20) mm v 0.96 (0.94) mm; p < 0.001. CONCLUSIONS: Plaques seem to be prone to rupture when the echolucent area is larger than 4.1 (3.2) mm 2, when the echolucent area to plaque ratio is greater than 38.5 (17.1)%, and when the fibrous cap is thinner than 0.7 mm. IVUS can identify plaque rupture and vulnerable plaques. This may influence patient management and treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.81.6.621

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 167

Metadata

Authors
Ge, J., Chirillo, F., Schwedtmann, J., Görge, G., Haude, M., Baumgart, D., Shah, V, von Birgelen, C., Sack, S., Boudoulas, H., & Erbel, R.
Venue
Heart
Publisher
BMJ
Published
1999-06-01
Volume
81
Issue
6
Pages
621-627
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2111564016
Cited by
167
References
2
FWCI
7.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound. https://app.cochat.ai/papers/10.1136/hrt.81.6.621
The paper
Ge, J., Chirillo, F., Schwedtmann, J., Görge, G., Haude, M., Baumgart, D., Shah, V, von Birgelen, C., Sack, S., Boudoulas, H., & Erbel, R. (1999). Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound. Heart. https://doi.org/10.1136/hrt.81.6.621

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.