The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High resolution in vivo intra-arterial imaging with optical coherence tomography
Open accessAbstract
BACKGROUND: Optical coherence tomography (OCT) is a new method of catheter based micron scale imaging. OCT is analogous to ultrasound, measuring the intensity of backreflected infrared light rather than sound waves. OBJECTIVE: To demonstrate the ability of OCT to perform high resolution imaging of arterial tissue in vivo. METHODS: OCT imaging of the abdominal aorta of New Zealand white rabbits was performed using a 2.9 F OCT imaging catheter. Using an ultrashort pulse laser as a light source for imaging, an axial resolution of 10 μm was achieved. RESULTS: Imaging was performed at 4 frames/second and data were saved in either super VHS or digital format. Saline injections were required during imaging because of the signal attenuation caused by blood. Microstructure was sharply defined within the arterial wall and correlated with histology. Some motion artefacts were noted at 4 frames/second. CONCLUSIONS: In vivo imaging of the rabbit aorta was demonstrated at a source resolution of 10 μm, but required the displacement of blood with saline. The high resolution of OCT allows imaging to be performed near the resolution of histopathology, offering the potential to have an impact both on the identification of high risk plaques and the guidance of interventional procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Self-citationHatsukami, T. S., Ross, R., Polissar, N. L., & Yuan, C. (2000) · Circulation · doi:10.1161/01.cir.102.9.959 · Cited by 622
Metadata
- Authors
- Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1999-08-01
- Volume
- 82
- Issue
- 2
- Pages
- 128-133
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2145444320
- Cited by
- 276
- References
- 1
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High resolution in vivo intra-arterial imaging with optical coherence tomography. https://app.cochat.ai/papers/10.1136/hrt.82.2.128
- The paper
- Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999). High resolution in vivo intra-arterial imaging with optical coherence tomography. Heart. https://doi.org/10.1136/hrt.82.2.128
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.