The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
High resolution in vivo intra-arterial imaging with optical coherence tomography
Open accessAbstract
BACKGROUND: Optical coherence tomography (OCT) is a new method of catheter based micron scale imaging. OCT is analogous to ultrasound, measuring the intensity of backreflected infrared light rather than sound waves. OBJECTIVE: To demonstrate the ability of OCT to perform high resolution imaging of arterial tissue in vivo. METHODS: OCT imaging of the abdominal aorta of New Zealand white rabbits was performed using a 2.9 F OCT imaging catheter. Using an ultrashort pulse laser as a light source for imaging, an axial resolution of 10 μm was achieved. RESULTS: Imaging was performed at 4 frames/second and data were saved in either super VHS or digital format. Saline injections were required during imaging because of the signal attenuation caused by blood. Microstructure was sharply defined within the arterial wall and correlated with histology. Some motion artefacts were noted at 4 frames/second. CONCLUSIONS: In vivo imaging of the rabbit aorta was demonstrated at a source resolution of 10 μm, but required the displacement of blood with saline. The high resolution of OCT allows imaging to be performed near the resolution of histopathology, offering the potential to have an impact both on the identification of high risk plaques and the guidance of interventional procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationThe Pathogenesis of Coronary Artery Disease and the Acute Coronary Syndromes
Epstein, F. H., Fuster, V., Badimon, L., Badimon, J. J., & Chesebro, J. H. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201303260506 · Cited by 3,725
Davies, M. J., & Thomas, A. C. (1985) · Heart · doi:10.1136/hrt.53.4.363 · Cited by 1,985
The pathogenesis of coronary artery disease and the acute coronary syndromes (First of two parts)
Fuster, V. (1992) · New England Journal of Medicine · Cited by 1,954
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
A technique for complete replacement of the ascending aorta
Bentall, H., & De Bono, A. (1968) · Thorax · doi:10.1136/thx.23.4.338 · Cited by 1,470
Waves and Fields in Optoelectronics
Bertolotti, M. (1985) · Optica Acta: International Journal of Optics · doi:10.1080/716099690 · Cited by 1,469
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Self-citationImaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Self-citationTopol, E. J., & Nissen, S. E. (1995) · Circulation · doi:10.1161/01.cir.92.8.2333 · Cited by 1,103
Waves and fields in optoelectronics
Haus, H. A. (1983) · Medical Entomology and Zoology · Cited by 1,009
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Self-citationNHLBI funding policies. Enhancing stability, predictability, and cost control.
Lenfant, C. (1994) · Circulation · doi:10.1161/01.cir.90.1.1 · Cited by 762
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Self-citationSubsurface Imaging of Living Skin with Optical Coherence Microscopy
Schmitt, J. M., Yadlowsky, M. J., & Bonner, R. F. (1995) · Dermatology · doi:10.1159/000246523 · Cited by 251
Brezinski, M. E., Tearney, G. J., Weissman, N. J., Boppart, S. A., Bouma, B. E., Hee, M. R., Weyman, A. E., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1997) · Heart · doi:10.1136/hrt.77.5.397 · Cited by 241
Self-citationCatheter-Based Optical Imaging of a Human Coronary Artery
Tearney, G. J., Brezinski, M. E., Boppart, S. A., Bouma, B. E., Weissman, N. J., Southern, J. F., Swanson, E. A., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.94.11.3013 · Cited by 115
Self-citation
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Self-citationOptical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Self-citationOptical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Self-citationJang, I.-K., Bouma, B. E., Kang, D.-H., Park, S.-J., Park, S.-W., Seung, K.-B., Choi, K.-B., Shishkov, M., Schlendorf, K., Pomerantsev, E., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01799-5 · Cited by 1,000
Self-citation
Metadata
- Authors
- Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1999-08-01
- Volume
- 82
- Issue
- 2
- Pages
- 128-133
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2145444320
- Cited by
- 276
- References
- 18
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.