Evaluation of an enzymatic method for determining creatinine in plasma.
Open accessAbstract
An enzymatic kit method for the determination of plasma creatinine was optimised for use with a centrifugal analyser and its performance characteristics and practicability compared with an end point and a kinetic Jaffé-based method. The enzymatic method exhibited several advantages over Jaffé-based methods--namely, smaller sample size, rapid sample throughput (200 per hour), and improved specificity. Glucose, acetoacetate, and cefoxitin did not interfere with the enzymatic method, although bilirubin did cause a negative interference which depended on both creatinine and bilirubin concentrations. The enzymatic method has particular clinical application in neonates, diabetic ketotic patients, and those receiving cephalosporins.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Creatinine was detected in sweat using a mixture of enzymes (creatininase, creatinase, and peroxidase) and a corresponding responsive dye (4-aminophenazone).
“Similarly, creatinine, a vital marker of hydration status and renal function, was detected in sweat using a mixture of enzymes (creatininase, creatinase, and peroxidase) and a corresponding responsive dye (4-aminophenazone) (Fig. 3E) (53).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [53]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Analytical Reviews in Clinical Biochemistry: The Estimation of Creatinine
SPENCER, K. M. (1986) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456328602300101 · Cited by 377 · see citing works
Gochman, N., & Schmitz, J. M. (1972) · Clinical Chemistry · doi:10.1093/clinchem/18.9.943 · Cited by 279 · see citing works
Kinetic serum creatinine assays. II. A critical evaluation and review.
Bowers, L. D., & Wong, E. T. (1980) · Clinical Chemistry · doi:10.1093/clinchem/26.5.555 · Cited by 219 · see citing works
Kinetic serum creatinine assays. II. A critical evaluation and review.
Bowers, L. D., & Wong, E. T. (1980) · Clinical Chemistry · doi:10.1093/clinchem/26.5.0555 · Cited by 189 · see citing works
Factors Influencing the Assay of Creatinine
Cook, J. G. (1975) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456327501200162 · Cited by 167 · see citing works
Guder, W., Hoffmann, G. E., Hubbuch, A., Poppe, W., Siedel, J., & Price, C. P. (1986) · PubMed · Cited by 75 · see citing works
Gerard, S. K., & Khayam-Bashi, H. (1985) · American Journal of Clinical Pathology · doi:10.1093/ajcp/84.5.659 · Cited by 62 · see citing works
Effects of bilirubin on detection of hydrogen peroxide by use of peroxidase.
Witte, D. L., Brown, L. F., & Feld, R. D. (1978) · Clinical Chemistry · doi:10.1093/clinchem/24.10.1778 · Cited by 60 · see citing works
Knapp, M. L., & Hadid, O. (1987) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456328702400114 · Cited by 56 · see citing works
Spain, M. A., & Wu, A. H. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.3.518 · Cited by 38 · see citing works
Letellier, G., & Desjarlais, F. (1985) · Clinical Biochemistry · doi:10.1016/s0009-9120(85)80074-6 · Cited by 32 · see citing works
Perlstein, M. T., Thibert, R. J., Watkins, R., et al. (1978) · Microchemical Journal · doi:10.1016/0026-265x(78)90035-8 · Cited by 17 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- Hoffman RG. Establishing quality control and normal ranges in the clinical laboratory. New York: Exposition Press, 1971.
- Gerard SK, Khayam-Bashi H. Characterization of creatinine error in ketotic patients. Am J Clin Pathol 1985;84:659-64.
Cited by
Sorted by citations
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308 · see citing works
- Authors
- Crocker, H., Shephard, M. D., & White, G. H.
- Affiliations
- Flinders Medical Centre (AU)
- ORCID
- Shephard, M D
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 1988-05
- Volume
- 41
- Issue
- 5
- Pages
- 576-581
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- PMC
- PMC1141516
- OpenAlex
- W2037545204
- Cited by
- 49
- References
- 12
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 5 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 4 · 2013: 2 · 2012: 2
- FWCI
- 0.61
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Clinical Pathology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Neonatal Health and Biochemistry
- Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
- Keywords
- serum creatinine, enzymatic creatinine assay, Jaffe method, centrifugal analyser, assay interference, bilirubin interference, neonates, diabetic ketoacidosis, cephalosporins, cefoxitin, sample throughput
- MeSH terms
- Acetoacetates, Adolescent, Bilirubin, Cefoxitin, Colorimetry, Creatinine, Female, Glucose, Humans, Infant, Methods, Reagent Kits, Diagnostic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review