The Taipan snake venom time: a new test for lupus anticoagulant.
Open accessThe DOI matches its Crossref record.
Abstract
AIMS--To develop a specific test for lupus anticoagulant activity with reduced sensitivity to coagulation factor deficiency that would be suitable for analysis of plasmas from patients receiving oral anticoagulants. METHODS--A coagulation test based on the Taipan snake venom time (TSVT) with a platelet neutralisation procedure (PNP) was developed and compared with dilute Russell's viper venom time (DRVVT). The TSVT was used to test plasmas from patients receiving oral anticoagulant or heparin with mild liver dysfunction and with documented lupus anticoagulant. RESULTS--The optimised conditions for the TSVT were established and a reference range was determined in normal healthy subjects. Results were considered positive for lupus anticoagulant if the ratio was > or = 1.1 and was reduced by > or = 10% or to < 1.1 in the PNP. In 43 samples from patients receiving oral anticoagulants there was no correlation between level of anticoagulation and TSVT, and only seven samples had increased TSVTs. Of these, five corrected on mixing with normal plasma and two gave equivocal results. The patients with mild liver dysfunction all had normal TSVTs. The TSVT in plasmas from patients receiving heparin correlated with the heparin concentrations (as measured by the APTT, r2 = 0.81). Some anticoagulated plasmas showed correction in the PNP and were regarded as false positive. Fourteen of 17 patients known to have lupus anticoagulant (on the basis of DRVVT results) were also positive by the TSVT; two of the remaining three were borderline and one was negative. CONCLUSIONS--The TSVT showed satisfactory intra-assay precision and reasonable sensitivity to lupus anticoagulant, compared with the DRVVT. The TSVT was influenced by the presence of heparin but was not sensitive to the effects of oral anticoagulant. Like other lupus anticoagulant tests, it does not seem to have a 100% detection rate, but this may be due to the presence of lupus anticoagulant subtypes with distinct activities or the requirement of cofactors other than prothrombin or beta 2 glycoprotein-I.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Self-citationGuidelines On The Investigation and Management Of The Antiphospholipid Syndrome
Greaves, M., Cohen, H., Machin, S. J., & Mackie, I. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02069.x · Cited by 294
Self-citationJoseph, J. E., Harrison, P., Mackie, I. J., Isenberg, D. A., & Machin, S. J. (2001) · British Journal of Haematology · doi:10.1046/j.1365-2141.2001.03101.x · Cited by 262
Self-citationRecent Guidelines and Recommendations for Laboratory Detection of Lupus Anticoagulants
Moore, G. (2014) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1364185 · Cited by 149
“20,28,33,38,41,72,73”
Diagnosis of antiphospholipid syndrome in routine clinical practice
Gardiner, C., Hills, J., Machin, S., & Cohen, H. (2013) · Lupus · doi:10.1177/0961203312460722 · Cited by 131
Laboratory Diagnosis of Antiphospholipid Syndrome: Insights and Hindrances
Vandevelde, A., & Devreese, K. M. J. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11082164 · Cited by 76
Cohen, H., Mackie, I. J., & Devreese, K. M. J. (2019) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14560 · Cited by 48
Self-citationMoore, G. W., Jones, P. O., Platton, S., Hussain, N., White, D., Thomas, W., Rigano, J., Pouplard, C., Gray, E., & Devreese, K. M. J. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15438 · Cited by 47
Current Controversies in Lupus Anticoagulant Detection
Moore, G. (2016) · Antibodies · doi:10.3390/antib5040022 · Cited by 36
“Combining TSVT and ecarin time (ET) with dRVVT and APTT mixing tests increases detection rates, partly because antibodies ‘lost’ by dilution can still manifest in TSVT/ET [5,6,63], and also because TSVT will detect a small proportion of LA unreactive with dRVVT and APTT [32,34,63,76].”
MethodTesting for Lupus Anticoagulants
Moore, G. W. (2022) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0042-1744363 · Cited by 30
Lupus Anticoagulant Detection under the Magnifying Glass
Molinari, A. C., Martini, T., Banov, L., Ierardi, A., Leotta, M., Strangio, A., & Santoro, R. C. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12206654 · Cited by 9
Analytical dilemmas in lupus anticoagulant detection
Moore, G. W. (2023) · Exploration of Immunology · doi:10.37349/ei.2023.00104 · Cited by 5
Lupus Anticoagulant Testing: Taipan Snake Venom Time with Ecarin Time as Confirmatory Test
Moore, G. W. (2023) · Methods in Molecular Biology · doi:10.1007/978-1-0716-3175-1_16 · Cited by 6
Viewpoint: Lupus anticoagulant detection and interpretation in antiphospholipid syndrome
Efthymiou, M., Bertolaccini, M. L., & Cohen, H. (2024) · Rheumatology · doi:10.1093/rheumatology/kead623 · Cited by 5
Metadata
- Authors
- Rooney, A. M., McNally, T., Mackie, I. J., & Machin, S. J.
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 1994-06
- Volume
- 47
- Issue
- 6
- Pages
- 497-501
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W2064300823
- Cited by
- 60
- References
- 0
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.