Evaluation of a novel endoluminal brush method for in situ diagnosis of catheter related sepsis.
Open accessThe DOI matches its Crossref record.
Abstract
AIMS: To determine the accuracy of a novel endoluminal brush method for the diagnosis of catheter related sepsis (CRS), which is performed in situ and hence does not require line sacrifice. METHODS: 230 central venous catheters in 216 patients were examined prospectively for evidence of CRS or colonisation using an endoluminal brush method in conjunction with peripheral blood cultures. The results were compared with those obtained using methods that require line sacrifice: extraluminal sampling (Maki roll) or endoluminal sampling (modified Cleri flush) of microorganisms. RESULTS: Only 16% of 128 patients suspected clinically of having line associated infection were confirmed as having CRS. In addition, 2 of 102 patients not suspected of having line associated infection had CRS. Line colonisation was apparent in approximately twice as many catheters using the Maki roll criteria (92%) compared with either the endoluminal brush (43%) or Cleri flush (43%). Furthermore, colonised catheters sampled using the Maki roll technique yielded mixed growth twice as often as when examined by endoluminal methods (17 and 8 cases, respectively). It was rare to detect either only endoluminal (4 of 22 episodes) or extraluminal (1 of 22 episodes) microorganisms in cases of CRS. In contrast, catheters defined as being colonised most frequently (59% of episodes) yielded only significant extraluminal growth. Only one case of CRS (5%) would have been "missed" if lines yielding a negative result from endoluminal brush sampling had been left in situ. Conversely, four episodes of CRS (18%) would not have been diagnosed by relying on extraluminal sampling alone. CONCLUSIONS: Diagnosis of CRS by the endoluminal brush method can be achieved without line sacrifice and is more sensitive (95%) and specific (84%) than extraluminal sampling of the catheter tip by the Maki roll technique (82% and 66%, respectively).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
Biofilm Formation: A Clinically Relevant Microbiological Process
Donlan, R. M. (2001) · Clinical Infectious Diseases · doi:10.1086/322972 · Cited by 1,343
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
Intravascular catheter-related infections: advances in diagnosis, prevention, and management
Raad, I., Hanna, H., & Maki, D. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70235-9 · Cited by 525
Meta-Analysis: Methods for Diagnosing Intravascular Device–Related Bloodstream Infection
Safdar, N., Fine, J. P., & Maki, D. G. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-6-200503150-00011 · Cited by 329
Catheter-related infections: diagnosis and intravascular treatment
Bouza, E., Burillo, A., & Muñoz, P. (2002) · Clinical Microbiology and Infection · doi:10.1046/j.1469-0691.2002.00385.x · Cited by 211
Management of complications in patients receiving home parenteral nutrition
Howard, L., & Ashley, C. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00326-3 · Cited by 204
Intravascular Catheter-Related Infections: New Horizons and Recent Advances
Raad, I. I., & Hanna, H. A. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.8.871 · Cited by 185
“Catheter-related bloodstream infections can also be diagnosed using an endoluminal brush technique that involves brushing the lumen of the catheter and using an acridine orange leukocyte cytospin test on blood drawn through colonized catheters.(45) The brush method had a sensitivity of 95% and a specificity of 84% in…”
MethodChaves, F., Garnacho-Montero, J., del Pozo, J. L., Bouza, E., Capdevila, J. A., de Cueto, M., Domínguez, M. Á., Esteban, J., Fernández-Hidalgo, N., Fernández Sampedro, M., et al. (2018) · Medicina Intensiva · doi:10.1016/j.medin.2017.09.012 · Cited by 170
“42,43,70---72 Endoluminal brushing, a method of sampling the internal surface of the catheter, showed high sensitivity (95---100”
Vanholder, R., Canaud, B., Fluck, R., Jadoul, M., Labriola, L., Marti-Monros, A., Tordoir, J., & Van Biesen, W. (2010) · Clinical Kidney Journal · doi:10.1093/ndtplus/sfq041 · Cited by 124
“Fibrin sheath or biofilm collection via endoluminal brushing has been proposed as another option [69,70] but has been criticized because of risk of arrhythmia, embolization and bacteraemia [71].”
Background
Metadata
- Authors
- Kite, P., Dobbins, B. M., Wilcox, M. H., Fawley, W. N., Kindon, A. J., Thomas, D., Tighe, M. J., & McMahon, M. J.
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 1997-04
- Volume
- 50
- Issue
- 4
- Pages
- 278-282
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W2069657550
- Cited by
- 109
- References
- 0
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.