Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 329

The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.

Meta-Analysis: Methods for Diagnosing Intravascular Device–Related Bloodstream Infection

Safdar, Nasia, Fine, Jason P., Maki, Dennis G. · 2005 · Annals of Internal Medicine

Abstract

BACKGROUND: No consensus exists on the best methods for diagnosis of intravascular device (IVD)-related bloodstream infection. PURPOSE: To identify the most accurate methods for diagnosis of IVD-related bloodstream infection. DATA SOURCES: 51 English-language studies published from 1966 to 31 July 2004. STUDY SELECTION: Studies of diagnostic tests for IVD-related bloodstream infection that described a reference standard and provided sufficient data to calculate sensitivity and specificity. DATA EXTRACTION: Study quality, diagnostic tests examined, patient characteristics, prevalence, sensitivity, and specificity. DATA SYNTHESIS: Pooled sensitivity and specificity were calculated for 8 diagnostic methods. Summary measures of accuracy were Q* (the upper leftmost point on the summary receiver-operating characteristic curve) and mean D (a log odds ratio). Subgroup analyses were used to assess heterogeneity. Overall, the most accurate test was paired quantitative blood culture (Q* = 0.94 [95% CI, 0.88 to 1.0]), followed by IVD-drawn quantitative [corrected] blood culture (Q* = 0.89 [CI, 0.79 to 0.99]) and the acridine orange leukocyte cytospin test (Q* = 0.89 [CI, 0.79 to 0.91]). The most accurate catheter segment culture test was quantitative culture (Q* = 0.87 [CI, 0.81 to 0.93]), followed by semi-quantitative culture (Q* = 0.84 [CI, 0.80 to 0.88]). Significant heterogeneity in pooled sensitivity and specificity was observed across all test categories. LIMITATIONS: The limited number of studies of some of the diagnostic methods precludes precise estimates of accuracy. CONCLUSIONS: Paired quantitative blood culture is the most accurate test for diagnosis of IVD-related bloodstream infection. However, most other methods studied showed acceptable sensitivity and specificity (both >0.75) and negative predictive value (>99%). The positive predictive value of all tests increased greatly with high pretest clinical probability. Catheters should not be cultured routinely but rather only if IVD-related bloodstream infection is suspected clinically.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-142-6-200503150-00011

Cites

66 of 66 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 66 references

Cited by

See all 329

Metadata

Authors
Safdar, N., Fine, J. P., & Maki, D. G.
Venue
Annals of Internal Medicine
Published
2005-03-15
Volume
142
Issue
6
Pages
451-466
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2039825164
Cited by
329
References
66
FWCI
32.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Meta-Analysis: Methods for Diagnosing Intravascular Device–Related Bloodstream Infection. https://app.cochat.ai/papers/10.7326/0003-4819-142-6-200503150-00011
The paper
Safdar, N., Fine, J. P., & Maki, D. G. (2005). Meta-Analysis: Methods for Diagnosing Intravascular Device–Related Bloodstream Infection. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-142-6-200503150-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.