The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electric source imaging of interictal activity accurately localises the seizure onset zone
Open accessAbstract
OBJECTIVE: It remains controversial whether interictal spikes are a surrogate of the seizure onset zone (SOZ). Electric source imaging (ESI) is an increasingly validated non-invasive approach for localising the epileptogenic focus in patients with drug-resistant epilepsy undergoing evaluation for surgery, using high-density scalp EEG and advanced source localisation algorithms that include the patient's own MRI. Here we investigate whether localisation of interictal spikes by ESI provides valuable information on the SOZ. METHODS: In 38 patients with focal epilepsy who later underwent intracranial EEG monitoring, we performed ESI of interictal spikes recorded with 128-256-channel EEG. We measured the distance between the ESI maximum and the nearest intracranial electrodes in the SOZ and irritative zone (IZ, the source of interictal spikes). The resection of the region harbouring the ESI maximum was correlated to surgical outcome. RESULTS: The median distance from the ESI maximum to the nearest electrode involved in the SOZ was 17 mm (IQR 8-27). The IZ and SOZ colocalised in most patients (median distance 0 mm, IQR 0-14), supporting the notion that localising interictal spikes is a valid surrogate for the SOZ. There was no difference in accuracy among patients with temporal or extratemporal epilepsy. In the 32 patients who underwent resective surgery, including the ESI maximum in the resection correlated with favourable outcome (p=0.03). CONCLUSIONS: Localisation of interictal spikes provides an excellent estimate of the SOZ in the majority of patients. ESI should be taken into account for the management of patients undergoing intracranial recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
Self-citation
Cited by
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Self-citationBrain imaging in the assessment for epilepsy surgery
Duncan, J. S., Winston, G. P., Koepp, M. J., & Ourselin, S. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(15)00383-x · Cited by 363
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Subcortical electrophysiological activity is detectable with high-density EEG source imaging
Seeber, M., Cantonas, L.-M., Hoevels, M., Sesia, T., Visser-Vandewalle, V., & Michel, C. M. (2019) · Nature Communications · doi:10.1038/s41467-019-08725-w · Cited by 294
Self-citation(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00006-0 · Cited by 134
Self-citation
Metadata
- Authors
- Megevand, P., Spinelli, L., Genetti, M., Brodbeck, V., Momjian, S., Schaller, K., Michel, C. M., Vulliemoz, S., & Seeck, M.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 2013-07-30
- Volume
- 85
- Issue
- 1
- Pages
- 38-43
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W2148278573
- Cited by
- 160
- References
- 1
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electric source imaging of interictal activity accurately localises the seizure onset zone. https://app.cochat.ai/papers/10.1136/jnnp-2013-305515
- The paper
- Megevand, P., Spinelli, L., Genetti, M., Brodbeck, V., Momjian, S., Schaller, K., Michel, C. M., Vulliemoz, S., & Seeck, M. (2014). Electric source imaging of interictal activity accurately localises the seizure onset zone. Journal of Neurology, Neurosurgery & Psychiatry. https://doi.org/10.1136/jnnp-2013-305515
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.