The basics of electromyography
Open accessThe DOI matches its Crossref record.
Abstract
Idrapril is the prototype of a new class of angiotensin converting enzyme (ACE) inhibitors. Its pharmacokinetics and pharmacodynamics (plasma ACE activity) were investigated in rats, dogs (after intravenous and oral doses), and human volunteers (after oral doses). Following intravenous administration (1 mg/kg) to rats and dogs, elimination half-lives were 96 and 52 min, systemic clearance 19.6 and 9.5 ml/min kg, and volume of distribution 2.7 and 0.8 liters/kg, respectively. Pharmacokinetics appeared linear in dogs, within the dose range of 0.1-10 mg/kg. After oral administration of similar doses (approximately 2 mg/kg) in the three species studied, peak plasma concentrations were 182, 567, and 726 ng/ml; AUCs 25, 85, and 182 micrograms min/ml; and elimination half-lives 82, 54, and 174 min in rats, dogs, and healthy volunteers, respectively. Absolute oral bioavailability was calculated to be approximately 24% in rats and dogs. Idrapril did not bind to plasma proteins of the species studied. Plasma ACE was fully inhibited following oral administration of approximately 2 mg/kg in rats and humans, but in dogs maximal inhibition did not exceed 85%. Duration of action, measured as time for ACE to recover to 70% of initial activity, was approximately 5, 3, and 22 hr in rats, dogs, and humans, respectively. Idrapril plasma levels appeared correlated in a saturable way with inhibition of plasma ACE in all three species, yielding ex vivo IC50 values of approximately 7 ng/ml for both the rat and humans, and 91 ng/ml for dogs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics
Faragó, P., Grama, L., Farago, M.-A., & Hintea, S. (2020) · Applied Sciences · doi:10.3390/app11010268 · Cited by 22
“5 mV, whereas re-innervation and intramuscular sprouting of chronic partial denervation results in MUAPs larger than 10 mV [43].”
BackgroundCorti, M., Smith, B. K., Falk, D. J., Lawson, L. A., Fuller, D. D., Subramony, S. H., Byrne, B. J., & Christou, E. A. (2015) · Muscle & Nerve · doi:10.1002/mus.24444 · Cited by 20
Surface Acoustic Wave (SAW) force myography sensor for muscle force output identification
Kohler, M. C., Voiculescu, I., & Li, F. (2024) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2024.115959 · Cited by 5
Metadata
- Authors
- Mills, K. R.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 2005-06-01
- Volume
- 76
- Issue
- suppl_2
- Pages
- ii32-ii35
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W2132392300
- Cited by
- 213
- References
- 0
- FWCI
- 0.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.