Walking is the most basic form of human activity for achieving mobility. As an essential function of the human body, the examination of walking is directed towards the assessment of body mechanics in posture and during movement. This work proposes a wearable smart system for the monitoring and objective evaluation of foot biomechanics during gait. The proposed solution assumes the cross-correlation of the plantar pressure with lower-limb muscular activity, throughout the stance phase of walking. Plantar pressure is acquired with an array of resistive pressure sensors deployed onto a shoe insole along the center of gravity progression line. Lower-limb muscular activity is determined from the electromyogram of the tibialis anterior and gastrocnemius lower limb muscles respectively. Under this scenario, physiological gait assumes the interdependency of plantar pressure on the heel area with activation of the tibialis anterior, as well as plantar pressure on the metatarsal arch/toe area with activation of the gastrocnemius. As such, assessment of gait physiology is performed by comparison of a gait map, formulated based on the footprint–lower-limb muscle cross-correlation results, to a reference gait template. A laboratory proof of concept validates the proposed solution in a test scenario which assumes a normal walking and two pathological walking patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




![Figure 5 Solutions of pressure sensor deployment on the footprint for dynamic assessment: ( a ) assessment of the footprint medial line with sensors deployed onto the hallux, metatarsal arch, lateral arch and heel respectively [13], ( b ) additional sensor deployed on the medial arch for flatfoot identification [14], ( c ) additional sensor deployed on the lesser toes and medial arch for flatfoot identification [15], ( d ) additional sensor deployed on the lesser toes [16]. Figure 5. Solutions of pressure sensor deployment on the footprint for dynamic assessment: ( a ) assessment of the footprint medial line with sensors deployed onto the hallux, metatarsal arch, lateral arch and heel respectively [13], ( b ) additional sensor deployed on the medial arch for flatfoot identification [14], ( c ) additional sensor deployed on the lesser toes and medial arch for flatfoot identification [15], ( d ) additional sensor deployed on the lesser toes [16].](https://figures.cochat.ai/paper-figures/5354f2ff07a04ccb8a168cc99a5d54ae/a-novel-wearable-foot-and-ankle-monitoring-system-for-the-assessment-of-gait-figure-5.png)



















Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“| Normal and pathological gait | Plantar pressure, activation of tibialis anterior and gastrocnemius muscles | EMG, Pressure sensor | 112 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [112]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rear-foot, mid-foot and fore-foot motion during the stance phase of gait
Leardini, A., Benedetti, M. G., Berti, L., Bettinelli, D., Nativo, R., & Giannini, S. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.017 · Cited by 692 · cited 1×
“model [32,33], and the Heidelberg measurement method [32,34].”
MethodCarson, M. C., Harrington, M. E., Thompson, N., O’Connor, J. J., & Theologis, T. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00101-4 · Cited by 550 · cited 1×
“[30] presents the evaluation of foot kinematics during barefoot walking based on a multi-segment foot model (12 foot parameters are evaluated) Ref.”
BackgroundIn-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array
Shu, L., Hua, T., Wang, Y., Li, Q., Feng, D. D., & Tao, X. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038904 · Cited by 416 · cited 7×
“Solutions of pressure sensor deployment on the footprint for static assessment: (a) three sensors deployed onto the forefoot, midfoot and heel [8], (b) three sensors for the forefoot and heel respectively—this solution was also employed in walking tests [6], and (c) sensor arrays deployed on the forefoot and heel to e…”
BackgroundMethodInfluentialA Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377 · cited 1×
“Both ZC and SSC can be accounted for as an indicator for the onset of movement [48,49].”
BackgroundDi Giulio, I., Maganaris, C. N., Baltzopoulos, V., & Loram, I. D. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.168690 · Cited by 237 · cited 1×
“In muscle activation, autogenic reflexes for postural control are particularly important [54].”
BackgroundThe Heidelberg foot measurement method: Development, description and assessment
Simon, J., Doederlein, L., McIntosh, A. S., Metaxiotis, D., Bock, H. G., & Wolf, S. I. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.07.003 · Cited by 223 · cited 2×
“[34] a protocol for measuring the kinematics of the foot and ankle (12 foot parameters are evaluated) Results and Accuracy No numerical values available, only graphs Muscles n.”
MethodKinematics and Electromyography of Lower Limb Muscles in Overground and Treadmill Running
Wank, V., Frick, U., & Schmidtbleicher, D. (1998) · International Journal of Sports Medicine · doi:10.1055/s-2007-971944 · Cited by 222 · cited 1×
“for treadmill running in [38] or by Prasad et al.”
MethodThe basics of electromyography
Mills, K. R. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.069211 · Cited by 213 · cited 1×
“5 mV, whereas re-innervation and intramuscular sprouting of chronic partial denervation results in MUAPs larger than 10 mV [43].”
BackgroundIdentification of Foot Pathologies Based on Plantar Pressure Asymmetry
Wafai, L., Zayegh, A., Woulfe, J., Aziz, S. M., & Begg, R. K. (2015) · Sensors · doi:10.3390/s150820392 · Cited by 182 · cited 2×
“The footprint accounts for ten anatomical areas which contribute to body weight support and body balance adjustment identified as: toe (1), lesser toes (2), metatarsophalangeal joints (3)–(7), midfoot (8), medial heel (9) and lateral heel (10), as illustrated in Figure 1 [5].”
BackgroundStep by Step Guide to Understanding the Kinetic Chain Concept in the Overhead Athlete
Ellenbecker, T. S., & Aoki, R. (2020) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-020-09615-1 · Cited by 114 · cited 2×
“As mentioned earlier, based on kinetic link principle, the human body must be considered in terms of a series of interrelated links or segments [28].”
Background
Research works printed but not linked: 6
- Kendal, F.P., Kendal McCreary, E., Provance, P.G., Rodgers, M.M., and Romani, W.A. (2005). Muscles: Testing and Testing and Function with Posture and Pain, Lippincott Williams & Wilkins. [5th ed.].
- Wei, 2000, A new system for foot pressure measurement and gait analysis, Chin. J. Biomed. Eng., 19, 32
- Maier, L. (2019). Portable Plantar Pressure Monitoring System Implemented with Arduino UNO (Original in Romanian: Sistem Portabil de Monitorizare a Presiunii Plantare Implementat cu Arduino UNO). [Diploma Thesis, Technical University of Cluj-Napoca].
- Qaqish, 2010, Foot Type and Tibialis Anterior Muscle Activity during Stance Phase of Gait, Int. J. Physiother. Rehabil., 1, 19
- Prasad, 2016, Foot and Ankle Kinematics and Dynamic Electromyography: Quantitative Analysis of Recovery from Peroneal Neuropathy in a Professional Football Player, J. Surg. Orthop. Adv., 25, 180
- Narwaria, 2011, Removal of Baseline Wander and Power Line Interference from ECG Signal—A Survey Approach, Int. J. Electron. Eng., 3, 107
Cited by
Ileșan, R. R., Cordoș, C.-G., Mihăilă, L.-I., Fleșar, R., Popescu, A.-S., Perju‐Dumbravă, L., & Faragó, P. (2022) · Biosensors · doi:10.3390/bios12040189 · Cited by 46
“Midstance; 4 Heel off—with pressure applied onto the metatarsal arch and hallux; 5 Toe off—with pressure applied only onto the hallux before lift-off [43].”
BackgroundMethodInfluentialSelf-citationCNN-Based Identification of Parkinson’s Disease from Continuous Speech in Noisy Environments
Faragó, P., Ştefănigă, S.-A., Cordoș, C.-G., Mihăilă, L.-I., Hintea, S., Peștean, A. S., Beyer, M., Perju‐Dumbravă, L., & Ileșan, R. R. (2023) · Bioengineering · doi:10.3390/bioengineering10050531 · Cited by 39
“where k is the segment index, n is the segment length (in samples), and nw is the total number of segments [56].”
BackgroundSelf-citationXu, L., Chen, J., Wang, F., Chen, Y., Yang, W., & Yang, C. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00898-0 · Cited by 22
Han, S., Xiao, Q., Ying, L., Chen, Y., Yan, F., Chen, H., Yue, J., Tian, X., & Xiong, Y. (2024) · Sensors · doi:10.3390/s24165189 · Cited by 24
“During a gait cycle, the foot acts as a dynamic platform for weight-bearing and propulsion, with the plantar surface experiencing varying levels of pressure distribution corresponding to different phases of movement [16].”
BackgroundOkoduwa, S. I. R., Igiri, B. E., Tagang, J., Okoduwa, U. J., & Adeyi, A. O. (2024) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2024.100311 · Cited by 17
Metadata
- Authors
- Faragó, P., Grama, L., Farago, M.-A., & Hintea, S.
- Affiliations
- Technical University of Cluj-Napoca (RO)
- University of Oradea (RO)
- Corresponding author
- Faragó, Paul
- Venue
- Applied Sciences
- Publisher
- MDPI AG
- Published
- 2020-12-29
- Volume
- 11
- Issue
- 1
- Pages
- 268
- ISSN
- 2076-3417 (ISSN-L)
- OpenAlex
- W3114637180
- Cited by
- 22
- References
- 47
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 4 · 2021: 4
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Applied Sciences (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- wearable gait monitoring, foot biomechanics, plantar pressure, electromyography, tibialis anterior, gastrocnemius, cross correlation function, resistive pressure sensors, insole sensors, gait analysis, pathological gait
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics. https://app.cochat.ai/papers/10.3390/app11010268
- The paper
- Faragó, P., Grama, L., Farago, M.-A., & Hintea, S. (2020). A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics. Applied Sciences. https://doi.org/10.3390/app11010268
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.