Stop using the Ashworth Scale for the assessment of spasticity
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
AIM: Many studies have been performed on the methodological qualities of the (modified) Ashworth Scale but overall these studies seem inconclusive. The aim of this study was to investigate the construct validity and inter-rater reliability of the Ashworth Scale (AS) for the assessment of spasticity in the upper and lower extremities. METHOD: A cross-sectional study on spasticity in the elbow flexors (part 1) and knee extensors (part 2) was carried out. In both parts AS was assessed while muscle activity and resistance were recorded simultaneously in patients with upper motor neuron syndrome. Each patient was measured by three raters. RESULTS: 30 patients participated, 19 in each part of the study. For elbow flexor muscles, AS was not significantly associated with electromyographic parameters, except for rater 2 (rho = 0.66, p<0.01). A significant moderate association was found with resistance (0.54< or = rho < or =0.61, p<0.05). For knee extensors, AS scores were moderately associated with muscle activity (0.56< or = rho < or =0.66, p<0.05) and also with resistance (0.55< or = rho < or =0.87, p<0.05). The intraclass correlation coefficient for absolute agreement was 0.58 for elbow flexors and 0.63 for knee extensors. In linear mixed model analysis, the factor rater appeared to be highly associated with AS. CONCLUSION: The validity and reliability of the AS is insufficient to be used as a measure of spasticity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Health Measurement Scales: A Practical Guide to Their Development and Use
Streiner, D. L., Norman, G. R., & Cairney, J. (1989) · Cited by 9,595
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213 · cited 1×
“9 electrode placement recommendations of the SENIAM-based protocol.[20] BR electrodes were placed at 1/4 of the line between the distal radius and the fossa cubit.”
MethodSelf-citationInterrater Reliability of a Modified Ashworth Scale of Muscle Spasticity
Bohannon, R. W., & Smith, M. B. (1987) · Physical Therapy · doi:10.1093/ptj/67.2.206 · Cited by 5,424
Health Measurement Scales--A Practical Guide to Their Development and Use
Waclawski, E. R. (2010) · Occupational Medicine · doi:10.1093/occmed/kqp179 · Cited by 1,874
PRELIMINARY TRIAL OF CARISOPRODOL IN MULTIPLE SCLEROSIS.
Ashworth, B. (1964) · PubMed · Cited by 1,475
Rankin, G., & Stokes, M. (1998) · Clinical Rehabilitation · doi:10.1191/026921598672178340 · Cited by 856
Pandyan, A. D., Johnson, G. R., Price, C. I. M., Curless, R. H., Barnes, M. P., & Rodgers, H. (1999) · Clinical Rehabilitation · doi:10.1191/026921599677595404 · Cited by 833
Zajicek, J., Fox, P., Sanders, H., Wright, D., Vickery, J., Nunn, A., & Thompson, A. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14738-1 · Cited by 827 · cited 1×
“An ICC of 0.63 can be considered insufficient for use in scientific research, in particular when used as a single outcome measure (eg, see Zajicek and colleagues”
MethodInfluentialSpastic movement disorder: impaired reflex function and altered muscle mechanics
Dietz, V., & Sinkjaer, T. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70193-x · Cited by 587
Accounting for Delusional Misidentifications
Ellis, H. D., & Young, A. W. (1990) · British Journal of Psychiatry · doi:10.1192/bjp.157.2.239 · Cited by 534
Cited by
The Promise of mHealth: Daily Activity Monitoring and Outcome Assessments by Wearable Sensors
Dobkin, B. H., & Dorsch, A. (2011) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968311425908 · Cited by 291
MUltiple Sclerosis and Extract of Cannabis: results of the MUSEC trial
Zajicek, J. P., Hobart, J. C., Slade, A., Barnes, D., Mattison, P. G., & on behalf of the MUSEC Research Group (2012) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2012-302468 · Cited by 278
Gunn, H. J., Newell, P., Haas, B., Marsden, J. F., & Freeman, J. A. (2013) · Physical Therapy · doi:10.2522/ptj.20120231 · Cited by 232
Aird, L., Samuel, D., & Stokes, M. (2012) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2012.03.005 · Cited by 218
Spasticity After Stroke: An Overview of Prevalence, Test Instruments, and Treatments
Sommerfeld, D. K., Gripenstedt, U., & Welmer, A.-K. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e31825f13a3 · Cited by 188
“It remains, however, to note that we do not yet have a good test to replace the MAS.(23) Although we continue to use the MAS in the clinic, we should be aware that we do not measure only neuronal components with the instrument but also, and probably to a greater extent, the peripheral biomechanical changes.”
MethodAgyapong-Badu, S., Warner, M., Samuel, D., & Stokes, M. (2016) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2015.09.011 · Cited by 167
“Clinical assessment of tone is subjective, using manual assessment by rating resistance to passive movement on scales such as the Modified Ashworth Scale (MAS) for stroke (Fleuren et al., 2010) and the Unified Parkinson’s disease Rating Scale (UPDRS) for PD (Goetz et al.”
MethodOtero-Romero, S., Sastre-Garriga, J., Comi, G., Hartung, H.-P., Soelberg Sørensen, P., Thompson, A. J., Vermersch, P., Gold, R., & Montalban, X. (2016) · Multiple Sclerosis Journal · doi:10.1177/1352458516643600 · Cited by 162
Metadata
- Authors
- Fleuren, J. F. M., Voerman, G. E., Erren-Wolters, C. V., Snoek, G. J., Rietman, J. S., Hermens, H. J., & Nene, A. V.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 2009-09-21
- Volume
- 81
- Issue
- 1
- Pages
- 46-52
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W2125065765
- Cited by
- 428
- References
- 18
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.