Stop using the Ashworth Scale for the assessment of spasticity
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
AIM: Many studies have been performed on the methodological qualities of the (modified) Ashworth Scale but overall these studies seem inconclusive. The aim of this study was to investigate the construct validity and inter-rater reliability of the Ashworth Scale (AS) for the assessment of spasticity in the upper and lower extremities. METHOD: A cross-sectional study on spasticity in the elbow flexors (part 1) and knee extensors (part 2) was carried out. In both parts AS was assessed while muscle activity and resistance were recorded simultaneously in patients with upper motor neuron syndrome. Each patient was measured by three raters. RESULTS: 30 patients participated, 19 in each part of the study. For elbow flexor muscles, AS was not significantly associated with electromyographic parameters, except for rater 2 (rho = 0.66, p<0.01). A significant moderate association was found with resistance (0.54< or = rho < or =0.61, p<0.05). For knee extensors, AS scores were moderately associated with muscle activity (0.56< or = rho < or =0.66, p<0.05) and also with resistance (0.55< or = rho < or =0.87, p<0.05). The intraclass correlation coefficient for absolute agreement was 0.58 for elbow flexors and 0.63 for knee extensors. In linear mixed model analysis, the factor rater appeared to be highly associated with AS. CONCLUSION: The validity and reliability of the AS is insufficient to be used as a measure of spasticity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Health Measurement Scales: A Practical Guide to Their Development and Use
Streiner, D. L., Norman, G. R., & Cairney, J. (1989) · Cited by 9,595
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213 · cited 1×
“9 electrode placement recommendations of the SENIAM-based protocol.[20] BR electrodes were placed at 1/4 of the line between the distal radius and the fossa cubit.”
MethodSelf-citationInterrater Reliability of a Modified Ashworth Scale of Muscle Spasticity
Bohannon, R. W., & Smith, M. B. (1987) · Physical Therapy · doi:10.1093/ptj/67.2.206 · Cited by 5,424
Health Measurement Scales--A Practical Guide to Their Development and Use
Waclawski, E. R. (2010) · Occupational Medicine · doi:10.1093/occmed/kqp179 · Cited by 1,874
PRELIMINARY TRIAL OF CARISOPRODOL IN MULTIPLE SCLEROSIS.
Ashworth, B. (1964) · PubMed · Cited by 1,475
Rankin, G., & Stokes, M. (1998) · Clinical Rehabilitation · doi:10.1191/026921598672178340 · Cited by 856
Pandyan, A. D., Johnson, G. R., Price, C. I. M., Curless, R. H., Barnes, M. P., & Rodgers, H. (1999) · Clinical Rehabilitation · doi:10.1191/026921599677595404 · Cited by 833
Zajicek, J., Fox, P., Sanders, H., Wright, D., Vickery, J., Nunn, A., & Thompson, A. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14738-1 · Cited by 827 · cited 1×
“An ICC of 0.63 can be considered insufficient for use in scientific research, in particular when used as a single outcome measure (eg, see Zajicek and colleagues”
MethodInfluentialSpastic movement disorder: impaired reflex function and altered muscle mechanics
Dietz, V., & Sinkjaer, T. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70193-x · Cited by 587
Accounting for Delusional Misidentifications
Ellis, H. D., & Young, A. W. (1990) · British Journal of Psychiatry · doi:10.1192/bjp.157.2.239 · Cited by 534
Hobart, J. C., Cano, S. J., Zajicek, J. P., & Thompson, A. J. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70290-9 · Cited by 495 · cited 1×
“However, its methodological limitations are now increasingly being acknowledged.[6, 7, 9, 10] While performing the test the joint under investigation is passively rotated and the examiner rates the perceived resistance during the movement.”
BackgroundRole of motoneurons in the generation of muscle spasms after spinal cord injury
Gorassini, M. A. (2004) · Brain · doi:10.1093/brain/awh243 · Cited by 256
Platz, T., Eickhof, C., Nuyens, G., & Vuadens, P. (2005) · Disability and Rehabilitation · doi:10.1080/09638280400014634 · Cited by 238
Haas, B. M., Bergström, E., Jamous, A., & Bennie, A. (1996) · Spinal Cord · doi:10.1038/sc.1996.100 · Cited by 203
Ashworth Scales are unreliable for the assessment of muscle spasticity
Ansari, N. N., Naghdi, S., Moammeri, H., & Jalaie, S. (2006) · Physiotherapy Theory and Practice · doi:10.1080/09593980600724188 · Cited by 170
Lower extremity skeletal muscle function in persons with incomplete spinal cord injury
Jayaraman, A., Gregory, C. M., Bowden, M. G., Stevens, J. E., Shah, P., Behrman, A. L., & Vandenborne, K. (2005) · Spinal Cord · doi:10.1038/sj.sc.3101892 · Cited by 87
Platz, T., Vuadens, P., Eickhof, C., Arnold, P. M., van Kaick, S., & Heise, K.-F. (2007) · Disability and Rehabilitation · doi:10.1080/09638280701191743 · Cited by 77
Fleuren, J. F. M., Nederhand, M. J., & Hermens, H. J. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.03.018 · Cited by 49
Self-citation
Cited by
The Promise of mHealth: Daily Activity Monitoring and Outcome Assessments by Wearable Sensors
Dobkin, B. H., & Dorsch, A. (2011) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968311425908 · Cited by 291
MUltiple Sclerosis and Extract of Cannabis: results of the MUSEC trial
Zajicek, J. P., Hobart, J. C., Slade, A., Barnes, D., Mattison, P. G., & on behalf of the MUSEC Research Group (2012) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2012-302468 · Cited by 278
Gunn, H. J., Newell, P., Haas, B., Marsden, J. F., & Freeman, J. A. (2013) · Physical Therapy · doi:10.2522/ptj.20120231 · Cited by 232
Aird, L., Samuel, D., & Stokes, M. (2012) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2012.03.005 · Cited by 218
Otero-Romero, S., Sastre-Garriga, J., Comi, G., Hartung, H.-P., Soelberg Sørensen, P., Thompson, A. J., Vermersch, P., Gold, R., & Montalban, X. (2016) · Multiple Sclerosis Journal · doi:10.1177/1352458516643600 · Cited by 162
Metadata
- Authors
- Fleuren, J. F. M., Voerman, G. E., Erren-Wolters, C. V., Snoek, G. J., Rietman, J. S., Hermens, H. J., & Nene, A. V.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 2009-09-21
- Volume
- 81
- Issue
- 1
- Pages
- 46-52
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W2125065765
- Cited by
- 428
- References
- 18
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.