Validity of questionnaire self-reports on computer, mouse and keyboard usage during a four-week period
Open accessThe DOI matches its Crossref record.
Abstract
Objective:To examine the validity and potential biases in self-reports of computer, mouse and keyboard usage times, compared with objective recordings. Methods:A study population of 1211 people was asked in a questionnaire to estimate the average time they had worked with computer, mouse and keyboard during the past four working weeks. During the same period, a software program recorded these activities objectively. The study was part of a one-year follow-up study from 2000–1 of musculoskeletal outcomes among Danish computer workers. Results:Self-reports on computer, mouse and keyboard usage times were positively associated with objectively measured activity, but the validity was low. Self-reports explained only between a quarter and a third of the variance of objectively measured activity, and were even lower for one measure (keyboard time). Self-reports overestimated usage times. Overestimation was large at low levels and declined with increasing levels of objectively measured activity. Mouse usage time proportion was an exception with a near 1:1 relation. Variability in objectively measured activity, arm pain, gender and age influenced self-reports in a systematic way, but the effects were modest and sometimes in different directions. Conclusion:Self-reported durations of computer activities are positively associated with objective measures but they are quite inaccurate. Studies using self-reports to establish relations between computer work times and musculoskeletal pain could be biased and lead to falsely increased or decreased risk estimates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parry, D. A., Davidson, B. I., Sewall, C. J. R., Fisher, J. T., Mieczkowski, H., & Quintana, D. S. (2021) · Nature Human Behaviour · doi:10.1038/s41562-021-01117-5 · Cited by 793
Berolo, S., Wells, R. P., & Amick, B. C. (2011) · Applied Ergonomics · doi:10.1016/j.apergo.2010.08.010 · Cited by 453
Computer work and musculoskeletal disorders of the neck and upper extremity: A systematic review
Wærsted, M., Hanvold, T. N., & Veiersted, K. B. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-79 · Cited by 306
Validated assessment tools for screen media use: a systematic review.
Perez, O., Garza, T., Hindera, O., Beltran, A., Musaad, S. M., Dibbs, T., Singh, A., Chug, S., Sisson, A., Kumar Vadathya, A., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0283714 · Cited by 44
“[46] used motion trackers to measure hand and arm movements while using the keyboard and mouse, summing them and equating these to total computer usage time.”
BackgroundMethodInfluentialWobbrock, J. O. (2014) · Advances in Medical Technologies and Clinical Practice · doi:10.4018/978-1-4666-4438-0.ch008 · Cited by 12
Metadata
- Authors
- Mikkelsen, S., Vilstrup, I., Lassen, C. F., Kryger, A. I., Thomsen, J. F., & Andersen, J. H.
- Venue
- Occupational and Environmental Medicine
- Publisher
- BMJ
- Published
- 2007-03-26
- Volume
- 64
- Issue
- 8
- Pages
- 541-547
- ISSN
- 0007-1072 (ISSN-L)
- 1351-0711
- 1470-7926
- OpenAlex
- W2012773025
- Cited by
- 67
- References
- 0
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of questionnaire self-reports on computer, mouse and keyboard usage during a four-week period. https://app.cochat.ai/papers/10.1136/oem.2005.026351
- The paper
- Mikkelsen, S., Vilstrup, I., Lassen, C. F., Kryger, A. I., Thomsen, J. F., & Andersen, J. H. (2007). Validity of questionnaire self-reports on computer, mouse and keyboard usage during a four-week period. Occupational and Environmental Medicine. https://doi.org/10.1136/oem.2005.026351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.