The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools.
Open accessAbstract
Possible relations between incidence and prevalence of sick building syndrome (SBS), indoor exposures, and personal factors were studied in a four year longitudinal study among personnel (n = 129) in six primary schools. The mean concentration of carbon dioxide was above the recommended value of 0.08 microliter/l (800 ppm) in all schools, indicating a poor outdoor air supply. Indoor concentration of volatile hydrocarbon (VOC) was enhanced at high room temperatures. Respirable dust, but not concentration of VOC was enhanced at lower ventilation rates and high air humidity. Chronic SBS was related to VOC, previous wall to wall carpeting in the schools, hyper-reactivity, and psychosocial factors. Incidence of new SBS was related to concentration of respirable dust, current smoking, and the psychosocial climate. Remission of hyperreactivity, decrease in sick leave owing to airway illness, removal of carpeting in the schools, and moving from new to old dwellings resulted in a decrease in SBS score. It is concluded that SBS is of multifactorial origin, related to a variety of factors and exposures. The total concentration of hydrocarbons is a simple and convenient measure of exposure, which also seems to be a predictor of chronic symptoms. Further investigations on the effect of temperature, ventilation, and air humidity on SBS should consider how these factors may influence the chemical composition of the air. Because poor air quality in schools could also affect the children, it may have implications for the state of health of a large proportion of the population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and variable selection in epidemiologic analysis
Greenland, S. (1989) · American Journal of Public Health · doi:10.2105/ajph.79.3.340 · Cited by 2,208
The use of analogue scales in rating subjective feelings
BOND, A., & LADER, M. (1974) · British Journal of Medical Psychology · doi:10.1111/j.2044-8341.1974.tb02285.x · Cited by 1,972
Cited by
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977
Concentrations of Volatile Organic Compounds in Indoor Air - A Review
Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00007.x · Cited by 559
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
“…indoor temperature and humidity, concentrations of chemical and microbiological pollutants, and amount of daylight (Pepler, 1968; Green, 1974, 1985; Norback et al., 1990; Ruotsalainen et al., 1995; Myhrvold et al., 1996; Myhrvold and Olsen, 1997; Smedje et al., 1997; Walinder et al., 1997a, 1997b,…”
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Metadata
- Authors
- Norback, D., Torgen, M., & Edling, C.
- Venue
- Occupational and Environmental Medicine
- Publisher
- BMJ
- Published
- 1990-11-01
- Volume
- 47
- Issue
- 11
- Pages
- 733-741
- ISSN
- 0007-1072 (ISSN-L)
- 1351-0711
- OpenAlex
- W2117924563
- Cited by
- 202
- References
- 2
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.