OBJECTIVE: To monitor the effect of a novel nicotine delivery device that may produce fewer carcinogens (Eclipse) on cigarette smoking, carbon monoxide and nicotine concentrations, and motivation to give up smoking. The smoker's own brand of cigarette and a nicotine replacement product (Nicotrol inhaler) were used as comparisons. DESIGN: After baseline data were recorded, smokers were randomised to either Eclipse or inhaler for two weeks and then switched to the other product for another two weeks. Thereafter a second baseline was obtained. SETTING AND PARTICIPANTS: Fifty smokers were included and data are reported for the 40 with complete data sets. The smokers were not trying to quit but were interested in trying a new product to reduce their risk. They visited a smoking clinic 10 times during the six week period of the trial. INTERVENTION: No counselling to aid reduction by Eclipse or inhaler was given. MAIN OUTCOME MEASURES: At each visit smoking status and carbon monoxide concentrations were recorded. In half of the visits withdrawal symptoms, attitudes towards smoking, heart rate, and blood nicotine concentrations were also recorded. RESULTS: Eclipse use decreased the number of cigarettes smoked per day (cpd) from 19.1 cpd at baseline to 2.1 cpd (p < 0.001), but increased carbon monoxide concentrations in parts per million (ppm) from 21.0 ppm to 33.0 ppm (p < 0.001). A similar decrease in cigarettes smoked per day was seen with the Nicotrol inhaler, from 19.1 cpd to 4.8 cpd (p < 0.001), but carbon monoxide decreased from 21.0 ppm to 12.7 ppm (p < 0.001). The blood nicotine concentration remained fairly stable with Eclipse, increasing slightly from 16.8 ng/ml to 18.0 ng/ml, while for the inhaler a significant drop was noted, from 16.8 ng/ml to 12. 2 ng/ml (p < 0.002). Craving and withdrawal did not increase with Eclipse. Few significant adverse events occurred with Eclipse. CONCLUSIONS: Eclipse can dramatically decrease cigarette consumption without causing withdrawal symptoms or decreases in nicotine concentrations or motivation to quit altogether. Unlike the inhaler, Eclipse produces an increase in carbon monoxide concentration. Thus Eclipse may not be a safer cigarette.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/tc.9.3.327

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 55

Metadata

Authors
Fagerstrom, K. O.
Venue
Tobacco Control
Publisher
BMJ
Published
2000-09-01
Volume
9
Issue
3
Pages
327-333
ISSN
0964-4563 (ISSN-L)
OpenAlex
W2148747028
Cited by
55
References
2
FWCI
1.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.