The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
Open accessAbstract
BACKGROUND: The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG. METHODS: Two hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal. RESULTS: The PSG derived apnoea hypopnea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated (R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnea definition, the mean (2SD) of the differences between RDI and AHI was -0.12 (15. 62)/h and the sensitivity and specificity profile did not change significantly. CONCLUSIONS: In a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,638
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
The Triad of Sleep Apnea, Hypertension, and Chronic Kidney Disease: A Spectrum of Common Pathology
Aziz, F., & Chaudhary, K. (2017) · Cardiorenal Medicine · doi:10.1159/000450796 · Cited by 3,267
Sleep Apnea and Hypertension: A Population-based Study
Hla, K. M., Young, T. B., Bidwell, T., Palta, M., Skatrud, J. B., & Dempsey, J. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-5-199403010-00005 · Cited by 551
Gould, G. A., Whyte, K. F., Rhind, G. B., Airlie, M. A. A., Catterall, J. R., Shapiro, C. M., & Douglas, N. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.4.895 · Cited by 480
Portable Recording in the Assessment of Obstructive Sleep Apnea
Ferber, R., Millman, R., Coppola, M., Fleetham, J., Murray, C. F., Iber, C., McCall, W. V., Nino-Murcia, G., Pressman, M., Sanders, M., et al. (1994) · Sleep · doi:10.1093/sleep/17.4.378 · Cited by 433
Clinical value of polysomnography
Douglas, N. J., Thomas, S., & Jan, M. A. (1992) · The Lancet · doi:10.1016/0140-6736(92)91660-z · Cited by 385
A Comparison of Clinical Assessment and Home Oximetry in the Diagnosis of Obstructive Sleep Apnea
Gyulay, S., Olson, L. G., Hensley, M. J., King, M. T., Allen, K. M., & Saunders, N. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.1.50 · Cited by 209
Measurement of Sleep-related Breathing Disturbances in Epidemiologic Studies
Redline, S., Tosteson, T., Boucher, M. A., & Millman, R. P. (1991) · Chest · doi:10.1378/chest.100.5.1281 · Cited by 206
Series, F., Marc, I., Cormier, Y., & La Forge, J. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-6-199309150-00001 · Cited by 196
Screening for Sleep Apnea Using Pulse Oximetry and A Clinical Score
Williams, A. J., Yu, G. W., Santiago, S., & Stein, M. (1991) · CHEST Journal · doi:10.1378/chest.100.3.631 · Cited by 155
Stoohs, R. A., & Guilleminault, C. (1992) · CHEST Journal · doi:10.1378/chest.101.5.1221 · Cited by 151
A Comparison of Apnea–Hypopnea Indices Derived from Different Definitions of Hypopnea
Tsai, W. H., Flemons, W. W., Whitelaw, W. A., & Remmers, J. E. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.9709017 · Cited by 124
White, D. P., Gibb, T. J., Wall, J. M., & Westbrook, P. R. (1995) · SLEEP · doi:10.1093/sleep/18.2.115 · Cited by 115
Comparisons of Home Sleep Recordings and Polysomnograms in Older Adults with Sleep Disorders
Sonia, A.-I., Daniel, F. K., Mason, W. J., & Messin, S. (1981) · SLEEP · doi:10.1093/sleep/4.3.283 · Cited by 108
Digital Monitoring of Sleep-disordered Breathing Using Snoring Sound and Arterial Oxygen Saturation
Issa, F., Morrison, D., Hadjuk, E., Iyer, A., Feroah, T. R., & Remmers, J. E. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.4_pt_1.1023 · Cited by 103
Value of nocturnal oxygen saturation as a screening test for sleep apnoea.
Cooper, B. G., Veale, D., Griffiths, C., & Gibson, G. J. (1991) · Thorax · doi:10.1136/thx.46.8.586 · Cited by 92
Ear Oximetry to Detect Apnea and Differentiate Rapid Eye Movement (REM) and Non-REM (NREM) Sleep
Farney, R. J., Walker, L. E., Jensen, R. L., & Walker, J. M. (1986) · CHEST Journal · doi:10.1378/chest.89.4.533 · Cited by 70
Orr, W. C., Eiken, T., Pegram, V., Jones, R., & Rundell, O. H. (1994) · CHEST Journal · doi:10.1378/chest.105.1.160 · Cited by 41
Cited by
Access to Diagnosis and Treatment of Patients with Suspected Sleep Apnea
Flemons, W. W., Douglas, N. J., Kuna, S. T., Rodenstein, D. O., & Wheatley, J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1124pp · Cited by 670
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Prevalence of obstructive sleep apnoea in men with type 2 diabetes
West, S. D., Nicoll, D. J., & Stradling, J. R. (2006) · Thorax · doi:10.1136/thx.2005.057745 · Cited by 374
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
Flemons, W. W. (2002) · New England Journal of Medicine · doi:10.1056/nejmcp012849 · Cited by 362
Metadata
- Authors
- Vazquez, J.-C.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2000-04-01
- Volume
- 55
- Issue
- 4
- Pages
- 302-307
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W1984055561
- Cited by
- 254
- References
- 21
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.