Volume effect and exertional dyspnoea after bronchodilator in patients with COPD with and without expiratory flow limitation at rest
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A study was undertaken to investigate whether bronchodilators are associated with less breathlessness at rest and during light exercise in patients with moderate to severe chronic obstructive pulmonary disease (COPD) with resting tidal expiratory flow limitation (EFL; flow limited (FL)) compared with those without EFL (non-flow limited (NFL)). METHODS: Twenty subjects (13 men) of mean (SD) age 65 (8) years (range 43-77) suffering from COPD with forced expiratory volume in 1 second (FEV(1)) 47 (18)% predicted were studied before and after inhalation of salbutamol (400 microg). Routine pulmonary function tests were performed in the seated position at rest. EFL was assessed by the negative expiratory pressure (NEP) method and changes in end expiratory lung volume (EELV) were inferred from variations in inspiratory capacity (IC). Dyspnoea was measured using the Borg scale at rest and at the end of a 6 minute steady state exercise test at 33% of the maximal predicted workload. RESULTS: EFL occurred in 11 patients. Following salbutamol IC did not change in NFL patients but increased by 24% (95% CI 15 to 33) in FL patients (p<0.001). Maximal inspiratory pressure (PImax) improved at EELV from 45 (95% CI 26 to 63) to 55 (95% CI 31 to 79) cm H(2)O (p<0.05) in FL patients after salbutamol but remained unchanged in NFL patients. The workload performed during exercise amounted to 34 (95% CI 27 to 41) and 31 (95% CI 21 to 40) watts (NS) for patients without and with EFL, respectively. After salbutamol, dyspnoea did not change either at rest or during exercise in the NFL patients, but decreased from 0.3 (95% CI -0.1 to 0.8) to 0.1 (95% CI -0.1 to 0.4) at rest (NS) and from 3.7 (95% CI 1.7 to 5.7) to 2.6 (95% CI 1.1 to 4.0) at the end of exercise (p<0.01) in FL patients. CONCLUSIONS: Patients with COPD with EFL may experience less breathlessness after a bronchodilator, at least during light exercise, than those without EFL. This beneficial effect, which is closely related to an increase in IC at rest, occurs even in the absence of a significant improvement in FEV(1) and is associated with a greater PImax.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Donnell, D. E., & Webb, K. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1351 · Cited by 543
Belman, M. J., Botnick, W. C., & Shin, J. W. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.153.3.8630581 · Cited by 402
Pulmonary mechanics during exercise in subjects with chronic airflow obstruction
Stubbing, D. G., Pengelly, L. D., Morse, J. L., & Jones, N. L. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.49.3.511 · Cited by 314
Cited by
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Ries, A. L. (2005) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1081/copd-200050655 · Cited by 405
O'Donnell, D. E., Voduc, N., Fitzpatrick, M., & Webb, K. A. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00072703 · Cited by 365
Detection of expiratory flow limitation in COPD using the forced oscillation technique
Dellacà, R. L., Santus, P., Aliverti, A., Stevenson, N., Centanni, S., Macklem, P. T., Pedotti, A., & Calverley, P. M. A. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00046804 · Cited by 351
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
“Subsequently, it has been shown that the increase in IC after anticholinergic and salbutamol therapy best reflects the improvement in exercise tolerance [ 47 ].”
BackgroundMethodInfluential
Metadata
- Authors
- Boni, E.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2002-06-01
- Volume
- 57
- Issue
- 6
- Pages
- 528-532
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W1973224637
- Cited by
- 105
- References
- 3
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.