Utility of overnight pulse oximetry and heart rate variability analysis to screen for sleep-disordered breathing in chronic heart failure

Open access
Ward, Neil R, Cowie, Martin R, Rosen, Stuart D, Roldao, Vitor, De Villa, Manuel, McDonagh, Theresa A, Simonds, Anita, Morrell, Mary J·2012·Thorax

Abstract

BACKGROUND: Sleep-disordered breathing (SDB) is under diagnosed in chronic heart failure (CHF). Screening with simple monitors may increase detection of SDB in a cardiology setting. This study aimed to evaluate the accuracy of heart rate variability analysis and overnight pulse oximetry for diagnosis of SDB in patients with CHF. METHODS: 180 patients with CHF underwent simultaneous polysomnography, ambulatory electrocardiography and wrist-worn overnight pulse oximetry. SDB was defined as an apnoea-hypopnoea index ≥15/h. To identify SDB from the screening tests, the per cent very low frequency increment (%VLFI) component of heart rate variability was measured with a pre-specified cutoff ≥2.23%, and the 3% oxygen desaturation index was measured with a pre-specified cutoff >7.5 desaturations/h. RESULTS: 173 patients with CHF had adequate sleep study data; SDB occurred in 77 (45%) patients. Heart rate variability was measurable in 78 (45%) patients with area under the %VLFI receiver operating characteristic curve of 0.50. At the ≥2.23% cutoff, %VLFI sensitivity was 58% and specificity was 48%. The 3% oxygen desaturation index was measurable in 171 (99%) patients with area under the curve of 0.92. At the pre-specified cutoff of >7.5 desaturations/h, the 3% oxygen desaturation index had a sensitivity of 97%, specificity of 32%, negative likelihood ratio of 0.08 and positive likelihood ratio of 1.42. Diagnostic accuracy was increased using a cutoff of 12.5 desaturations/h, with sensitivity of 93% and specificity of 73%. CONCLUSIONS: The high sensitivity and low negative likelihood ratio of the 3% oxygen desaturation index indicates that pulse oximetry would be of use as a simple screening test to rule out SDB in patients with CHF in a cardiology setting. The %VLFI component of heart rate variability is not suitable for detection of SDB in CHF.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thoraxjnl-2012-201684

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In 173 CHF patients, at an ODI3% cutoff >7.5 desaturations/h, sensitivity was 97%, specificity 32%, negative likelihood ratio 0.08, and positive likelihood ratio 1.42.

    “The results demonstrated that at the cutoff of >7.5 desaturations/h, the ODI3% had a sensitivity 97%, a specificity 32%, a negative likelihood ratio 0.08, and a positive likelihood ratio 1.42.”

    From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [623]

    The Diagnostic accuracy of overnight pulse oximetry section reports all four figures at the >7.5 desaturations/h cutoff. The Abstract distinguishes the 173 patients with adequate sleep-study data from the 171 whose ODI could be analysed, so the claim's sample size for these test results is imprecise. (LLM, conf=0.90)

    Experimental — accuracy not yet measured
  • In the Ward et al. CHF study, diagnostic accuracy increased at an ODI3% cutoff of 12.5 desaturations/h, with sensitivity 93% and specificity 73%.

    “The diagnostic accuracy increased using a cutoff of 12.5 desaturations/h, with a sensitivity 93% and a specificity 73%.”

    From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [623]

  • In the Ward et al. CHF study, ODI3% had an AUC of 0.92 (95% CI 0.88-0.96) for detecting SDB in CHF at a cutoff >7.5 desaturations/h.

    “The ODI3% had an AUC of 0.92 (95% C.I. 0.88–0.96) for the detection of SDB in CHF, at the cutoff of >7.5 desaturations/h.”

    From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [623]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ward, N. R., Cowie, M. R., Rosen, S. D., Roldao, V., De Villa, M., McDonagh, T. A., Simonds, A., & Morrell, M. J.
Affiliations
Royal Brompton Hospital (GB)
Corresponding author
Ward, Neil R
Venue
Thorax
Publisher
BMJ
Published
2012-07-17
Volume
67
Issue
11
Pages
1000-1005
ISSN
  • 0040-6376 (ISSN-L)
  • 1468-3296
OpenAlex
W2115592583
Cited by
38
References
47
Citations by year
2026: 2 · 2024: 2 · 2023: 3 · 2022: 5 · 2021: 4 · 2020: 1 · 2019: 3 · 2018: 2 · 2016: 7 · 2015: 5 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
1.93
Type
journal article
Language
en
Open access
Locations
  • Thorax (publishedVersion)
  • PubMed (publishedVersion)
  • HighWire Press Open Archive (submittedVersion)
Funders
  • Royal Brompton and Harefield NHS Foundation Trust
  • National Institute for Health and Care Research
  • British Heart Foundation
  • Imperial College London
  • National Heart and Lung Institute
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
sleep-disordered breathing, chronic heart failure, overnight pulse oximetry, heart rate variability, oxygen desaturation index, screening, diagnostic accuracy, apnea-hypopnea index, polysomnography
MeSH terms
Aged, Algorithms, Chronic Disease, Female, United Kingdom, Heart Failure, Heart Rate, Humans, Male, Mass Screening, Middle Aged, Oximetry, Predictive Value of Tests, Sensitivity and Specificity, Severity of Illness Index, Sleep Apnea Syndromes, Electrocardiography, Ambulatory, Polysomnography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review