Objective measurement of compliance during oral appliance therapy for sleep-disordered breathing
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Oral appliance (OA) therapy is increasingly prescribed as a non-continuous positive airway pressure treatment modality for sleep-disordered breathing (SDB). Although OA therapy is reported to be efficacious for the treatment of SDB, data on compliance remain limited to self-report. METHODS: In this 3-month prospective clinical trial, the main outcome was to assess the safety and feasibility of an objective measurement of compliance during OA therapy using an embedded microsensor thermometer with on-chip integrated readout electronics in 51 consecutive patients with an established diagnosis of SDB (AHI 18.0 ± 11.9/h; age 47 ± 10 y; BMI 26.6 ± 4.0 kg/m(2); men/women: 31/20). Patients were unaware of the purpose of the study. RESULTS: No microsensor-related adverse events were recorded. In addition, no problems were encountered during the readout of the compliance data. Out of 51 microsensors, one had a technical defect and was lost to follow-up. In this study, the overall objective mean rate of OA use was 6.6 ± 1.3 h per day with a regular OA users' rate of 82% at the 3-month follow-up. Statistical analysis revealed no significant differences between objective and self-reported OA compliance data in this study. Measurement of the objective OA compliance allowed us to calculate the mean disease alleviation (MDA) as the product of objective compliance and therapeutic efficacy. MDA serves as a measure of the overall therapeutic effectiveness, and turned out to be 51.1%. CONCLUSIONS: The results illustrate the safety and feasibility of objective measurement of OA compliance. The objective measurement of OA compliance allows for calculation of the MDA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973
McNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Obstructive Sleep Apnea as a Risk Factor for Stroke and Death
Yaggi, H. K., Concato, J., Kernan, W. N., Lichtman, J. H., Brass, L. M., & Mohsenin, V. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043104 · Cited by 3,004
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Adherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Weaver, T. E., & Grunstein, R. R. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-119mg · Cited by 1,680
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Kushida, C. A., Morgenthaler, T. I., Littner, M. R., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2006) · Sleep · doi:10.1093/sleep/29.2.240 · Cited by 749
Efficacy of Positive Airway Pressure and Oral Appliance in Mild to Moderate Obstructive Sleep Apnea
Barnes, M., McEvoy, R. D., Banks, S., Tarquinio, N., Murray, C. G., Vowles, N., & Pierce, R. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200311-1571oc · Cited by 597
The effect of mandibular advancement on upper airway structure in obstructive sleep apnoea
Chan, A. S. L., Sutherland, K., Schwab, R. J., Zeng, B., Petocz, P., Lee, R. W. W., Darendeliler, M. A., & Cistulli, P. A. (2010) · Thorax · doi:10.1136/thx.2009.131094 · Cited by 356
Gotsopoulos, H., Kelly, J. J., & Cistulli, P. A. (2004) · Sleep · doi:10.1093/sleep/27.5.934 · Cited by 340
Sleep {middle dot} 2: Pathophysiology of obstructive sleep apnoea/hypopnoea syndrome
Fogel, R. B. (2004) · Thorax · doi:10.1136/thorax.2003.015859 · Cited by 291
Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea
Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200701-114oc · Cited by 289
Self-citationTitrated mandibular advancement versus positive airway pressure for sleep apnoea
Gagnadoux, F., Fleury, B., Vielle, B., Pételle, B., Meslier, N., N’Guyen, X. L., Trzepizur, W., & Racineux, J. L. (2009) · European Respiratory Journal · doi:10.1183/09031936.00148208 · Cited by 275
PÉPIN, J. L., KRIEGER, J., RODENSTEIN, D., CORNETTE, A., SFORZA, E., DELGUSTE, P., DESCHAUX, C., GRILLIER, V., & LÉVY, P. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.4.9802027 · Cited by 274
Obesity Hypoventilation Syndrome: Mechanisms and Management
Piper, A. J., & Grunstein, R. R. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201008-1280ci · Cited by 247
Jennum, P., & Kjellberg, J. (2011) · Thorax · doi:10.1136/thx.2010.143958 · Cited by 240 · cited 1×
“As a result, SDB has major socioeconomic consequences.(6) OSA is characterised by repetitive pharyngeal collapse (apnoea) or upper airway narrowing (hypopnoea) during sleep, leading to hypoxaemia and hypercapnia, and causing sleep fragmentation that in turn leads to daytime sleepiness and increased risk of motor vehic…”
BackgroundRyan, C. F., Love, L. L., Peat, D., Fleetham, J. A., & Lowe, A. A. (1999) · Thorax · doi:10.1136/thx.54.11.972 · Cited by 239
Non-CPAP therapies in obstructive sleep apnoea: mandibular advancement device therapy
Marklund, M., Verbraecken, J., & Randerath, W. (2012) · European Respiratory Journal · doi:10.1183/09031936.00144711 · Cited by 239
Treatment, airway and compliance effects of a titratable oral appliance.
Lowe, A. A., Sjöholm, T. T., Ryan, C. F., Fleetham, J. A., Ferguson, K. A., & Remmers, J. E. (2000) · PubMed · Cited by 189
Therapy with nCPAP: incomplete elimination of Sleep Related Breathing Disorder
Grote, L., Hedner, J., Grunstein, R., & Kraiczi, H. (2000) · European Respiratory Journal · doi:10.1183/09031936.00.16592100 · Cited by 182
Petit, F.-X., Pépin, J.-L., Bettega, G., Sadek, H., Raphaël, B., & Lévy, P. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2008167 · Cited by 174
Comparison of Adjustable and Fixed Oral Appliances for the Treatment of Obstructive Sleep Apnea
Lettieri, C. J., Paolino, N. D., Eliasson, A. H., Shah, A. A., & Holley, A. B. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1300 · Cited by 172
George, C. F. P. (2004) · Thorax · doi:10.1136/thx.2003.007187 · Cited by 164
Ravesloot, M. J. L., & de Vries, N. (2011) · Sleep · doi:10.1093/sleep/34.1.105 · Cited by 138
Dieltjens, M., Vanderveken, O. M., de Heyning, P. V., & Braem, M. J. A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.06.002 · Cited by 138
Self-citationObstructive sleep apnea as a risk factor for stroke and death
Tiberge, M. (2005) · Médecine du Sommeil · doi:10.1016/s1769-4493(05)70131-x · Cited by 127
Sleep-Related Breathing Disorders
Orr, W. C. (2002) · CHEST Journal · doi:10.1378/chest.121.1.8 · Cited by 116
Grunstein, R. R. (1995) · Thorax · doi:10.1136/thx.50.10.1106 · Cited by 95
Sleep {middle dot} 6: Obstructive sleep apnoea/hypopnoea syndrome and hypertension
Robinson, G. V. (2004) · Thorax · doi:10.1136/thx.2003.015875 · Cited by 90
Dieltjens, M., Vanderveken, O. M., Hamans, E., Verbraecken, J. A., Wouters, K., Willemen, M., Backer, W. A. D., de Heyning, P. V., & Braem, M. J. A. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0721-3 · Cited by 67
Self-citationObjective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome
Krieger, J., & Kurtz, D. (1988) · European Respiratory Journal · doi:10.1183/09031936.93.01050436 · Cited by 58
Inoko, Y., YOSHIMURA, K., Kato, C., Morita, O., & Kohno, M. (2009) · Sleep and Biological Rhythms · doi:10.1111/j.1479-8425.2009.00402.x · Cited by 26
Smith, D. M., & Stradling, J. R. (2002) · Thorax · doi:10.1136/thorax.57.4.305 · Cited by 25
Complexity and Efficacy of Mandibular Advancement Splints: Understanding their Mode of Action
de Almeida, F. R. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1302 · Cited by 24
Brown, L. K. (2011) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0b013e32834bdf6e · Cited by 5
Cited by
Obstructive sleep apnoea syndrome
Lévy, P., Kohler, M., McNicholas, W. T., Barbé, F., McEvoy, R. D., Somers, V. K., Lavie, L., & Pépin, J.-L. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.15 · Cited by 1,235
Phillips, C. L., Grunstein, R. R., Darendeliler, M. A., Mihailidou, A. S., Srinivasan, V. K., Yee, B. J., Marks, G. B., & Cistulli, P. A. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201212-2223oc · Cited by 572
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
“12,107 These micro-sensors, embedded into the OA m , represent a significant tech - nological advance and are commercially available.”
InfluentialSelf-citationInternational Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Self-citationEuropean position paper on drug-induced sedation endoscopy (DISE)
De Vito, A., Carrasco Llatas, M., Vanni, A., Bosi, M., Braghiroli, A., Campanini, A., de Vries, N., Hamans, E., Hohenhorst, W., Kotecha, B. T., et al. (2014) · Sleep and Breathing · doi:10.1007/s11325-014-0989-6 · Cited by 295
Self-citation
Metadata
- Authors
- Vanderveken, O. M., Dieltjens, M., Wouters, K., De Backer, W. A., Van de Heyning, P. H., & Braem, M. J.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2012-09-19
- Volume
- 68
- Issue
- 1
- Pages
- 91-96
- ISSN
- 0040-6376 (ISSN-L)
- 1468-3296
- OpenAlex
- W2129935477
- Cited by
- 297
- References
- 39
- FWCI
- 20.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.