Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Withdrawal of fluticasone propionate from combined salmeterol/fluticasone treatment in patients with COPD causes immediate and sustained disease deterioration: a randomised controlled trial

Open access
Wouters, E F M·2005·Thorax

Abstract

BACKGROUND: Guidelines recommend inhaled corticosteroids (ICS) as maintenance treatment for patients with chronic obstructive pulmonary disease (COPD) with a post-bronchodilator forced expiratory volume in 1 second (FEV1) <50% predicted and frequent exacerbations, although they have only a small preventive effect on the accelerated decline in lung function. Combined treatment with ICS and long acting beta2 agonists (LABA) may provide benefit to the stability of COPD, but it is unknown if withdrawal of ICS will result in disease deterioration. METHODS: The effects of 1 year withdrawal of the ICS fluticasone propionate (FP) after a 3 month run-in treatment period with FP combined with the LABA salmeterol (S) (500 microg FP + 50 microg S twice daily; SFC) were investigated in patients with COPD in a randomised, double blind study. 497 patients were enrolled from 39 centres throughout the Netherlands; 373 were randomised and 293 completed the study. RESULTS: The drop out rate after randomisation was similar in the two groups. Withdrawal of FP resulted in a sustained decrease in FEV1: mean (SE) change from baseline -4.4 (0.9)% (S) v -0.1 (0.9)% (SFC); adjusted difference 4.1 (95% CI 1.6 to 6.6) percentage points (p<0.001). Corresponding figures for the FEV1/FVC ratio were -3.7 (0.8)% (S) v 0.0 (0.8)% (SFC) (p = 0.002). The annual moderate to severe exacerbation rate was 1.6 and 1.3 in the S and SFC groups, respectively (adjusted rate ratio 1.2; 95% CI 0.9 to 1.5; p = 0.15). The mean annual incidence rate of mild exacerbations was 1.3 (S) v 0.6 (SFC), p = 0.020. An immediate and sustained increase in dyspnoea score (scale 0-4; mean difference between groups 0.17 (0.04), p<0.001) and in the percentage of disturbed nights (6 (2) percentage points, p<0.001) occurred after withdrawal of fluticasone. CONCLUSIONS: Withdrawal of FP in COPD patients using SFC resulted in acute and persistent deterioration in lung function and dyspnoea and in an increase in mild exacerbations and percentage of disturbed nights. This study clearly indicates a key role for ICS in the management of COPD as their discontinuation leads to disease deterioration, even under treatment with a LABA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.2004.034280

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 263

Metadata

Authors
Wouters, E. F. M.
Venue
Thorax
Publisher
BMJ
Published
2005-06-01
Volume
60
Issue
6
Pages
480-487
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2136593482
Cited by
263
References
30
FWCI
14.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.