Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 253

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Temporal relationship between air pollutants and hospital admissions for chronic obstructive pulmonary disease in Hong Kong

Open access
Ko, F. W S, Tam, W., Wong, T. W., Chan, D. P S, Tung, A. H, Lai, C. K W, Hui, D. S C·2007·Thorax

Abstract

AIMS: To assess any relationship between the levels of ambient air pollutants and hospital admissions for chronic obstructive pulmonary disease (COPD) in Hong Kong. METHODS: A retrospective ecological study was undertaken. Data of daily emergency hospital admissions to 15 major hospitals in Hong Kong for COPD and indices of air pollutants (sulphur dioxide (SO(2)), nitrogen dioxide (NO(2)), ozone (O(3)), particulates with an aerodynamic diameter of <10 microm (PM(10)) and 2.5 microm (PM(2.5))) and meteorological variables from January 2000 to December 2004 were obtained from several government departments. Analysis was performed using generalised additive models with Poisson distribution, adjusted for the effects of time trend, season, other cyclical factors, temperature and humidity. Autocorrelation and overdispersion were corrected. RESULTS: Significant associations were found between hospital admissions for COPD with all five air pollutants. Relative risks for admission for every 10 microg/m(3) increase in SO(2), NO(2), O(3), PM(10) and PM(2.5) were 1.007, 1.026, 1.034, 1.024 and 1.031, respectively, at a lag day ranging from lag 0 to cumulative lag 0-5. In a multipollutant model, O(3), SO(2) and PM(2.5) were significantly associated with increased admissions for COPD. SO(2), NO(2) and O(3) had a greater effect on COPD admissions in the cold season (December to March) than during the warm season. CONCLUSION: Ambient concentrations of air pollutants have an adverse effect on hospital admissions for COPD in Hong Kong, especially during the winter season. This might be due to indoor exposure to outdoor pollution through open windows as central heating is not required in the mild winter. Measures to improve air quality are urgently needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.2006.076166

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 253

Metadata

Authors
Ko, F. W. S., Tam, W., Wong, T. W., Chan, D. P. S., Tung, A. H., Lai, C. K. W., & Hui, D. S. C.
Venue
Thorax
Publisher
BMJ
Published
2007-09-01
Volume
62
Issue
9
Pages
780-785
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2162487812
Cited by
253
References
3
FWCI
7.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temporal relationship between air pollutants and hospital admissions for chronic obstructive pulmonary disease in Hong Kong. https://app.cochat.ai/papers/10.1136/thx.2006.076166
The paper
Ko, F. W. S., Tam, W., Wong, T. W., Chan, D. P. S., Tung, A. H., Lai, C. K. W., & Hui, D. S. C. (2007). Temporal relationship between air pollutants and hospital admissions for chronic obstructive pulmonary disease in Hong Kong. Thorax. https://doi.org/10.1136/thx.2006.076166

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.