Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
RATIONALE: The SenseWear armband (SAB) is designed to measure energy expenditure (EE). In people with chronic obstructive pulmonary disease (COPD), EE estimated using the SAB (EE(SAB)) is a popular outcome measure. However, a detailed analysis of the measurement properties of the SAB in COPD is lacking. OBJECTIVE: To examine the sensitivity of EE(SAB), agreement between EE(SAB) and EE measured via indirect calorimetry (EE(IC)), and its repeatability in COPD. METHODS: 26 people with COPD (forced expiratory volume in 1 s (FEV(1))=49+/-18% predicted; 15 males) spent 6 min in five standardised tasks that comprised supine, sitting, standing and two walking speeds. A subgroup (n=12) walked using a rollator. Throughout each task, measurements of EE(SAB) and EE(IC) were collected. The protocol was repeated on a second day. RESULTS: EE(SAB) increased between standing and slow walking (2.4, metabolic equivalents (METs) 95% CI 2.2 to 2.7) as well as slow and fast walking (0.5 METs, 95% CI 0.3 to 0.7). Considering all tasks together, the difference between EE(SAB) and EE(IC) was -0.2 METs (p=0.21) with a limit of agreement of 1.3 METs. The difference between days in EE(SAB) was 0.0 METs with a coefficient of repeatability of 0.4 METs. Rollator use increased the variability in EE(SAB), compromising its repeatability and agreement with EE(IC). CONCLUSIONS: EE(SAB) was sensitive to small but important changes. There was fair agreement between EE(SAB) and EE(IC), and measurements of EE(SAB) were repeatable. These observations suggest that the SAB is useful for the evaluation of EE in patients with COPD who walk without a rollator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 2×
“In the absence of significant F ratios, we proceeded with analysis for agreement using methods described by Bland and Altman.(20) A similar procedure was used to examine repeatability.”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925
Characteristics of physical activities in daily life in chronic obstructive pulmonary disease
Pitta, F., Troosters, T., Spruit, M. A., Probst, V. S., Decramer, M., & Gosselink, R. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-855oc · Cited by 1,256 · cited 1×
“13 An assessment was lacking of the sensitivity of the SAB to detect the difference in EE associated with changing from standing to walking at slow speeds.(14) Repeatability of measurements over 2 days was not examined.”
BackgroundRedelmeier, D. A., Bayoumi, A. M., Goldstein, R. S., & Guyatt, G. H. (1997) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.155.4.9105067 · Cited by 1,029 · cited 8×
“increase in distance walked as a consequence of the increased speed (ie, 84 m) is likely to be considered important by individuals with COPD.(23) Given the excellent repeatability of the measurements of EESAB, a clinician could confidently detect differences resulting from small changes in walking speed of a patient.”
BackgroundInfluentialSelf-citation
Cited by
Spruit, M. A., Singh, S. J., Garvey, C., ZuWallack, R., Nici, L., Rochester, C., Hill, K., Holland, A. E., Lareau, S. C., Man, W. D.-C., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201309-1634st · Cited by 3,938
Self-citationPhysical Activity Is the Strongest Predictor of All-Cause Mortality in Patients With COPD
Waschki, B., Kirsten, A., Holz, O., Müller, K.-C., Meyer, T., Watz, H., & Magnussen, H. (2011) · Chest · doi:10.1378/chest.10-2521 · Cited by 951
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
An official European Respiratory Society statement on physical activity in COPD
Watz, H., Pitta, F., Rochester, C. L., Garcia-Aymerich, J., ZuWallack, R., Troosters, T., Vaes, A. W., Puhan, M. A., Jehn, M., Polkey, M. I., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00046814 · Cited by 526
Holland, A. E., Mahal, A., Hill, C. J., Lee, A. L., Burge, A. T., Cox, N. S., Moore, R., Nicolson, C., O'Halloran, P., Lahham, A., et al. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-208514 · Cited by 446
Metadata
- Authors
- Hill, K., Dolmage, T. E., Woon, L., Goldstein, R., & Brooks, D.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2010-06-01
- Volume
- 65
- Issue
- 6
- Pages
- 486-491
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2167807154
- Cited by
- 135
- References
- 6
- FWCI
- 9.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease. https://app.cochat.ai/papers/10.1136/thx.2009.128702
- The paper
- Hill, K., Dolmage, T. E., Woon, L., Goldstein, R., & Brooks, D. (2010). Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease. Thorax. https://doi.org/10.1136/thx.2009.128702
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.