The DOI matches its Crossref record.
Histamine dose-response curves in asthma: reproducibility and sensitivity of different indices to assess response.
Open accessAbstract
In 18 clinically stable asthmatic patients histamine inhalation challenges were performed with a Wright's nebuliser and tidal volume breathing for two minutes on two to four occasions for each subject at a maximum interval of two weeks. The response was measured in terms of specific lung conductance (sGL) by the subtraction technique, maximum partial and maximum complete expiratory flow at 40% and 50% of vital capacity respectively (Vmax40p and Vmax50c), and FEV1 from the maximum flow-volume curve. Dose-response curves were analysed for (1) provocative concentration (PC) of histamine causing a 20% fall in FEV1 and a 40% change in the other measurements; (2) threshold concentration (TC)--the concentration at which changes in the measurement exceed 2 SD from control values; (3) reactivity (R)--the slope of the dose-response curve beyond TC. We found that PC20-FEV1 was the most reproducible index, the 95% confidence intervals based on a single determination being +/- 1.6 single two-fold concentration difference. PC20-FEV1 was more reproducible than PC values for other measurements and more reproducible than any of the TC values. The 95% confidence intervals based on a single determination of R varied from +/- 52% to +/- 74% change/log histamine concentration. Both sGL and Vmax40p detected the bronchoconstrictor response assessed by PC and TC at a significantly lower histamine concentration than FEV1 (p less than 0.01 and p less than 0.05 respectively). PC and TC results showed a significant correlation, but neither were correlated with R.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.1.ats11-99 · Cited by 2,467
Standardized challenge testing with pharmacological, physical and sensitizing stimuli in adults
Sterk, P. J., Fabbri, L. M., Quanjer, P. H., Cockcroft, D. W., O'Byrne, P. M., Anderson, S. D., Juniper, E. F., & Malo, J.-L. (1993) · European Respiratory Journal · doi:10.1183/09041950.053s1693 · Cited by 1,049
Self-citationDiagnosis and Management of Work-Related Asthma
Tarlo, S. M., Balmes, J., Balkissoon, R., Beach, J., Beckett, W., Bernstein, D., Blanc, P. D., Brooks, S. M., Cowl, C. T., Daroowalla, F., et al. (2008) · Chest · doi:10.1378/chest.08-0201 · Cited by 547
Statistics in respiratory medicine. 2. Repeatability and method comparison.
Chinn, S. (1991) · Thorax · doi:10.1136/thx.46.6.454 · Cited by 360
Joos, G. F., & O'Connor, B. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00008403 · Cited by 353
Metadata
- Authors
- Dehaut, P., Rachiele, A., Martin, R. R., & Malo, J. L.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1983-07-01
- Volume
- 38
- Issue
- 7
- Pages
- 516-522
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2016835468
- Cited by
- 193
- References
- 0
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histamine dose-response curves in asthma: reproducibility and sensitivity of different indices to assess response. https://app.cochat.ai/papers/10.1136/thx.38.7.516
- The paper
- Dehaut, P., Rachiele, A., Martin, R. R., & Malo, J. L. (1983). Histamine dose-response curves in asthma: reproducibility and sensitivity of different indices to assess response. Thorax. https://doi.org/10.1136/thx.38.7.516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.