CoChat

Evaluation of Biox IIA ear oximeter.

Open access
Tweeddale, P M, Douglas, N J · 1985 · Thorax
Cited by 33

The DOI matches its Crossref record.

Abstract

Arterial blood gas tensions, pH, and carboxyhaemoglobin were measured on 322 occasions in 165 patients and the actual oxygen saturation of the haemoglobin (Sao2) was compared with the ear oxygen saturation (SEO2) recorded during the arterial sampling with a Biox IIA ear oximeter. The overall agreement between SEO2 and Sao2 was good, with a mean difference in saturation (SEO2-Sao2) of + 1.5% (SD 3.0). The difference in saturation remained similar at all levels of arterial saturation observed and was unaffected by carboxyhaemoglobin concentration. On four occasions (1% of readings), however, SEO2 and Sao2 differed by more than 10% and such occasional errors might be misleading in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.40.11.825

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 33

Metadata

Authors
Tweeddale, P. M., & Douglas, N. J.
Venue
Thorax
Publisher
BMJ
Published
1985-11-01
Volume
40
Issue
11
Pages
825-827
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2163514378
Cited by
33
References
0
FWCI
6.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Biox IIA ear oximeter. https://app.cochat.ai/papers/10.1136/thx.40.11.825
The paper
Tweeddale, P. M., & Douglas, N. J. (1985). Evaluation of Biox IIA ear oximeter. Thorax. https://doi.org/10.1136/thx.40.11.825

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.