Cited by 145Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyOptical Imaging and Spectroscopy Techniques

Skin color and ear oximetry

Ries, Andrew L., Prewitt, Lela M., Johnson, Jeffery J.·1989·Chest

Abstract

Measurements of arterial blood oxygen saturation from two ear oximeters were compared with 655 simultaneously drawn arterial blood samples in 187 patients grouped by skin color quantified by the Munsell color system. Technical problems including warning lights and messages with the two ear oximeters were recorded. There were significantly more technical problems in patients with the darkest skin color associated with inability to obtain a reading or warning message indicating poor tissue penetration of the signal (18 and 15 percent vs 1 percent). When readings could be obtained, the ear oximetry readings were found to be slightly less accurate in the darker patient groups. These findings suggest that dark skin color may affect the performance and accuracy of ear oximeters, including the newer type of pulse oximeters.

Integrity signals

Registry

Crossref · 10.1378/chest.96.2.287

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ries, A. L., Prewitt, L. M., & Johnson, J. J.
Affiliations
University of California San Diego (US)
Corresponding author
Ries, Andrew L.
Venue
Chest
Publisher
Elsevier BV
Published
1989-08
Volume
96
Issue
2
Pages
287-290
ISSN
0012-3692 (ISSN-L)
OpenAlex
W1966473319
Cited by
145
References
10
Citations by year
2026: 6 · 2025: 8 · 2024: 13 · 2023: 7 · 2022: 37 · 2021: 7 · 2020: 6 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 3 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 1
FWCI
6.00
Type
journal article
Language
en
Open access
closed
Locations
  • CHEST Journal (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Center for Research Resources (RR00827)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
ear oximetry, skin color, dark skin pigmentation, arterial oxygen saturation, pulse oximetry, Munsell color system, measurement accuracy, technical errors
MeSH terms
Blood Gas Monitoring, Transcutaneous, Ear, External, Exercise Test, Humans, Lung Diseases, Prospective Studies, Skin Pigmentation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review