Evaluation of the Ohmeda 3700 pulse oximeter.
Open accessThe DOI matches its Crossref record.
Abstract
Arterial oxygen saturation values (Sao2) from 60% to 98% were measured by the Ohmeda 3700 pulse oximeter with the three types of probe available and compared with values of oxygen saturation estimated from direct arterial sampling (arterial oxygen and carbon dioxide tensions and pH) on 65 occasions. The response time of the oximeter was measured after a sudden rise in inspired oxygen concentration. Artefact rejection was assessed by arterial compression proximal to the probe site, and by simultaneous recordings of overnight Sao2 on opposite hands. The ability to recreate patterns of oscillating Sao2 from the data stored in the oximeter was also investigated. With the best probe system the oximeter measured Sao2, relative to arterial values estimated from Pao2, with a mean (SD) difference of -0.4% (1.8%). The response time was comparable with those of previous oximeters. It was not possible to generate artefactual dips in excess of 2% Sao2, and the dual overnight recordings rarely showed even small dips on one tracing alone. The stored data can recreate oscillating Sao2 signals with wavelengths down to about 35 seconds, but not below. The Ohmeda 3700 pulse oximeter appears to be suitable for unattended overnight recordings of Sao2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Snoring, sleep disturbance, and behaviour in 4-5 year olds.
Ali, N. J., Pitson, D. J., & Stradling, J. R. (1993) · Archives of Disease in Childhood · doi:10.1136/adc.68.3.360 · Cited by 883
Self-citationPredictors and prevalence of obstructive sleep apnoea and snoring in 1001 middle aged men.
Stradling, J. R., & Crosby, J. H. (1991) · Thorax · doi:10.1136/thx.46.2.85 · Cited by 640
Self-citationDavies, R. J., Ali, N. J., & Stradling, J. R. (1992) · Thorax · doi:10.1136/thx.47.2.101 · Cited by 479
Self-citationSTRADLING, J. (1990) · The Lancet · doi:10.1016/0140-6736(90)90068-g · Cited by 399
Self-citationSleep disordered breathing: Effects of adenotonsillectomy on behaviour and psychological functioning
Ali, N. J., Pitson, D., & Stradling, J. R. (1996) · European Journal of Pediatrics · doi:10.1007/bf02115629 · Cited by 367
Self-citationOvernight Pulse Oximetry for Sleep-Disordered Breathing in Adults
Netzer, N., Eliasson, A. H., Netzer, C., & Kristo, D. A. (2001) · Chest · doi:10.1378/chest.120.2.625 · Cited by 311
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Kelleher, J. F. (1989) · Journal of Clinical Monitoring · doi:10.1007/bf01618369 · Cited by 202
Cerebrovascular Consequences of Obstructive Sleep Apnea
Durgan, D. J., & Bryan, R. M. (2012) · Journal of the American Heart Association · doi:10.1161/jaha.111.000091 · Cited by 197
“The delay time for pulse oximetry, which depends on manufacturer, sampling interval, and probe placement, can be ≥30 seconds.(90,91) Contrary to the majority of studies that show an increase in CBFV during OSA, Netzer et al(92) reported that CBFV decreased during 76% of obstructive hypopneas and 80% of obstructive”
BackgroundAccuracy of Oximetry for Detection of Respiratory Disturbances in Sleep Apnea Syndrome
Lévy, P., Louis Pépin, J., Deschaux-Blanc, C., Paramelle, B., & Brambilla, C. (1996) · Chest · doi:10.1378/chest.109.2.395 · Cited by 188
Metadata
- Authors
- Warley, A. R., Mitchell, J. H., & Stradling, J. R.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1987-11-01
- Volume
- 42
- Issue
- 11
- Pages
- 892-896
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2164313596
- Cited by
- 73
- References
- 0
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.