The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.
Open accessAbstract
BACKGROUND The metered dose inhaler is difficult to use correctly, synchronising actuation with inhalation being the most important problem. A breath actuated pressurised inhaler, designed to help patients with poor inhaler technique, was compared with a conventional metered dose inhaler in terms of aerosol deposition and bronchodilator response. METHODS Radioaerosol deposition and bronchodilator response to 100 micrograms salbutamol were measured in 18 asthmatic patients, who inhaled from a conventional metered dose inhaler by their own chosen metered dose inhaler technique, from a conventional metered dose inhaler by a taught metered dose inhaler technique, and from a breath actuated pressured inhaler (Autohaler). RESULTS In the 10 patients who could coordinate actuation and inhalation of the inhaler on their own deposition of aerosol in the lungs and bronchodilator response were equivalent on the three study days. By contrast, in the eight patients who could not coordinate the mean (SEM) percentage of the dose deposited in the lungs with their own inhaler technique (7.2% (3.4%] was substantial lower than those attained by the taught metered dose inhaler technique (22.8% (2.5%] and by Autohaler (20.8% (1.7%]. CONCLUSION Although of little additional benefit to asthmatic patients with good coordination, the Autohaler is potentially a valuable aid to those with poor coordination, and should be considered in preference to a conventional metered dose inhaler in any patient whose inhaler technique is not known to be satisfactory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glantz, S. A. (1981) · Cited by 2,636
Errors in Inhalation Technique and Efficiency in Inhaler Use in Asthmatic Children
Pedersen, S., Frost, L., & Arnfred, T. (1986) · Allergy · doi:10.1111/j.1398-9995.1986.tb00287.x · Cited by 200
Effects of various inhalation modes on the deposition of radioactive pressurized aerosols.
Newman, S. P., Pavia, D., GARLAND, N., & Clarke, S. W. (1982) · PubMed · Cited by 172
Self-citationPressurised aerosol deposition in the human lung with and without an "open" spacer device.
Newman, S. P., Clark, A. R., Talaee, N., & Clarke, S. W. (1989) · Thorax · doi:10.1136/thx.44.9.706 · Cited by 153
Self-citationSpacer Devices Used with Metered-Dose Inhalers
König, P. (1985) · CHEST Journal · doi:10.1378/chest.88.2.276 · Cited by 144
Clinical consequences of inadequate inhalation technique in asthma therapy.
Lindgren, S., Bake, B., & Larsson, S. (1987) · PubMed · Cited by 141
Cited by
National Asthma Education and Prevention Program
VanGraafeiland, B. (2002) · The Nurse Practitioner · doi:10.1097/00006205-200206001-00003 · Cited by 1,091
Inhaler mishandling remains common in real life and is associated with reduced disease control
Melani, A. S., Bonavia, M., Cilenti, V., Cinti, C., Lodi, M., Martucci, P., Serra, M., Scichilone, N., Sestini, P., Aliani, M., et al. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.01.005 · Cited by 947
What the pulmonary specialist should know about the new inhalation therapies
Laube, B. L., Janssens, H. M., de Jongh, F. H. C., Devadason, S. G., Dhand, R., Diot, P., Everard, M. L., Horvath, I., Navalesi, P., Voshaar, T., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00166410 · Cited by 806
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
Giraud, V., & Roche, N. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00218402 · Cited by 538
Metadata
- Authors
- Newman, S. P., Weisz, A. W., Talaee, N., & Clarke, S. W.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1991-10-01
- Volume
- 46
- Issue
- 10
- Pages
- 712-716
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2107462455
- Cited by
- 326
- References
- 6
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.