Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 578

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size

Usmani, Omar S., Biddiscombe, Martyn F., Barnes, Peter J.·2005·American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Aerosol particle size influences the extent, distribution, and site of inhaled drug deposition within the airways. OBJECTIVES: We hypothesized that targeting albuterol to regional airways by altering aerosol particle size could optimize inhaled bronchodilator delivery. METHODS: In a randomized, double-blind, placebo-controlled study, 12 subjects with asthma (FEV1, 76.8 +/- 11.4% predicted) inhaled technetium-99m-labeled monodisperse albuterol aerosols (30-microg dose) of 1.5-, 3-, and 6-microm mass median aerodynamic diameter, at slow (30-60 L/min) and fast (> 60 L/min) inspiratory flows. Lung and extrathoracic radioaerosol deposition were quantified using planar gamma-scintigraphy. Pulmonary function and tolerability measurements were simultaneously assessed. Clinical efficacy was also compared with unlabeled monodisperse albuterol (15-microg dose) and 200 microg metered-dose inhaler (MDI) albuterol. RESULTS: Smaller particles achieved greater total lung deposition (1.5 microm [56%], 3 microm [50%], and 6 microm [46%]), farther distal airways penetration (0.79, 0.60, and 0.36, respective penetration index), and more peripheral lung deposition (25, 17, and 10%, respectively). However, larger particles (30-microg dose) were more efficacious and achieved greater bronchodilation than 200 microg MDI albuterol (deltaFEV1 [ml]: 6 microm [551], 3 microm [457], 1.5 microm [347], MDI [494]). Small particles were exhaled more (1.5 microm [22%], 3 microm [8%], 6 microm [2%]), whereas greater oropharyngeal deposition occurred with large particles (15, 31, and 43%, respectively). Faster inspiratory flows decreased total lung deposition and increased oropharyngeal deposition for the larger particles, with less bronchodilation. A shift in aerosol distribution to the proximal airways was observed for all particles. CONCLUSIONS: Regional targeting of inhaled beta2-agonist to the proximal airways is more important than distal alveolar deposition for bronchodilation. Altering intrapulmonary deposition through aerosol particle size can appreciably enhance inhaled drug therapy and may have implications for developing future inhaled treatments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200410-1414oc

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 578

Metadata

Authors
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2005-12-15
Volume
172
Issue
12
Pages
1497-1504
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2118957675
Cited by
578
References
19
FWCI
9.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size. https://app.cochat.ai/papers/10.1164/rccm.200410-1414oc
The paper
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005). Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200410-1414oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.