The science of nebulised drug delivery
Open accessAbstract
Effective nebuliser therapy requires a device distinguished from a simple atomiser by the incorporation of baffles which selectively re-that repeatedly and quickly delivers sufficient drug to the site of action, with minimal wastage, move large droplets from the outgoing spray.9 Early models were essentially atomisers con-at a low cost.Clinicians are bombarded with competing claims about different nebuliser sys-structed of glass and operated manually by compressing a hand bulb attached to the air tems.In many cases, however, insufficient details are available to make the most appropriate inlet tube.10 In 1946 pumps providing a continuous flow of air were advocated and the choice.The rapid increase in the number of nebulisers marketed and significant differences Collinson nebuliser, 11 constructed of ebonite with a plate baffle to filter out particles larger in design may result in drug delivery to patients varying by a factor of two or more. 1 than 5 m, became the most popular nebuliser in this country.In 1958 Wright 12 described a new nebuliser, considerably more compact than the Collinson, with a moulded perspex top.Drug delivery from nebulisers Most of the prescribed medication for nebu-Now discontinued, it found widespread use in bronchial challenge testing.13 14 lisers never reaches the lungs. 2 Of the dose placed in the nebuliser chamber, perhaps twoWith the advent of portable, oil free compressors and injection moulding of plastics, a thirds remains there at the end of nebulisation.Two thirds of the dose released from the nebu-wide variety of disposable nebulisers has become available.Recent advances in their liser may be released during expiration and passes into the surrounding air. 3 Some of the design have considerably altered the amount of drug patients receive.inhaled drug will be in particles too large to reach the lung, and some in particles so small that they do not deposit but are simply exhaled again.With many nebulisers only 10% of the In a jet nebuliser the driving gas passes through prescribed dose may reach the lung.4 For bronchodilators, where a small dose may a very narrow hole, known as a Venturi, from a high pressure system (fig 1).At the Venturi achieve an adequate result, this may not matter.It is more important for drugs with dose related the pressure falls and the gas velocity increases greatly producing a cone shaped front.This effects (and side effects) such as steroids, and for expensive medications such as rhDNase.5 passes at high velocity over the end of a narrow liquid feed tube or concentric feeding system creating a negative pressure at this point.As a result of this fall in pressure, liquid is sucked Nebuliser types: how they work [6][7][8] Nebulisers used in aerosol drug delivery pro-up by the Bernoulli effect (see Appendix 1)and is drawn out into fine ligaments.The duce a polydisperse aerosol where most of the drug released is contained in particles 1-5 m ligaments then collapse into droplets under the influence of surface tension.This primary in diameter.Most nebulisers use compressed air for atomisation (fig 1), but some use ultra-generation (atomisation) typically produces droplets 15-500 m in diameter.15 Coarse sonic energy (fig 2). A nebuliser may be
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bates, D. V., Fish, B., Hatch, T. F., Mercer, T. T., & Morrow, P. E. (1966) · PubMed · Cited by 771
Stahlhofen, W., Gebhart, J., & Heyder, J. (1980) · American Industrial Hygiene Association Journal · doi:10.1080/15298668091424933 · Cited by 444
Deposition and Retention Models for Internal Dosimetry of the Human Respiratory Tract
(1966) · Health Physics · doi:10.1097/00004032-196602000-00005 · Cited by 312
Aerosol deposition considerations in inhalation therapy
Newman, S. P. (1985) · Chest · doi:10.1378/chest.88.2.152s · Cited by 264
RYAN, G. F., DOLOVICH, M. B., Roberts, R. S., Frith, P. A., Juniper, E. F., Hargreave, F. E., & Newhouse, M. T. (1981) · PubMed · doi:10.1164/arrd.1981.123.2.195 · Cited by 205
Factors influencing the size distribution of aerosols from jet nebulisers.
Clay, M. M., Pavia, D., Newman, S. P., & Clarke, S. W. (1983) · Thorax · doi:10.1136/thx.38.10.755 · Cited by 203
RYAN, G. F., DOLOVICH, M. B., Obminski, G., Cockcroft, D., Juniper, E. F., Hargreave, F. E., & Newhouse, M. T. (1981) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(81)90012-9 · Cited by 200
Selroos, O., & Halme, M. K. (1991) · Thorax · doi:10.1136/thx.46.12.891 · Cited by 148
Clark, A. R. (1995) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(94)00255-4 · Cited by 145
Smaldone, G. C., Fuhrer, J., Steigbigel, R. T., et al. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.4_pt_1.727 · Cited by 119
Jet and ultrasonic nebuliser output: use of a new method for direct measurement of aerosol output.
Dennis, J., Stenton, S., Beach, J. R., Avery, A. J., Walters, E. H., & Hendrick, D. J. (1990) · Thorax · doi:10.1136/thx.45.10.728 · Cited by 115
Modelling and algebraic formulation of regional aerosol deposition in man
Rudolf, G., Köbrich, R., & STAHLHOFEN, W. (1990) · Journal of Aerosol Science · doi:10.1016/0021-8502(90)90266-z · Cited by 110
Everard, M. L., Hardy, J. G., & Milner, A. D. (1993) · Thorax · doi:10.1136/thx.48.10.1045 · Cited by 89
Gonda, I. (2003) · Drugs and the pharmaceutical sciences · doi:10.1201/9780203912898.ch3 · Cited by 85
Lung deposition from four nebulizers
Hardy, J. G., Newman, S. P., & Knoch, M. (1993) · Respiratory Medicine · doi:10.1016/0954-6111(93)90074-a · Cited by 68
Importance of Evaporative Water Losses During Standardized Nebulized Inhalation Provocation Tests
Cockcroft, D. W., Hurst, T. S., & Gore, B. M. (1989) · CHEST Journal · doi:10.1378/chest.96.3.505 · Cited by 67
The nasal distribution of metered does inhalers
Newman, S. P., Morén, F., & Clarke, S. W. (1987) · The Journal of Laryngology & Otology · doi:10.1017/s0022215100101380 · Cited by 67
Validity of methods used to test airway responsiveness in children
Souëf, P. N. L. (1992) · The Lancet · doi:10.1016/0140-6736(92)91602-5 · Cited by 66
Effect of nebulised aerosol size on lung deposition in patients with mild asthma.
Clay, M., & Clarke, S. W. (1987) · Thorax · doi:10.1136/thx.42.3.190 · Cited by 61
Chemical breakdown of technetium-99m DTPA during nebulization.
Waldman, D. L., Weber, D. A., Oberdörster, G., Drago, S. R., Utell, M. J., Hyde, R. W., & Morrow, P. E. (1987) · PubMed · Cited by 31
Aerosol deposition and airway obstruction.
Love, R. G., & Dc, M. (1976) · PubMed · doi:10.1164/arrd.1976.114.5.891 · Cited by 25
ANIMAL STUDIES WITH ENVIRONMENTAL AEROSOLS
Brain, J. D. (1993) · Journal of Aerosol Medicine · doi:10.1089/jam.1993.6.33 · Cited by 8
Cited by
Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults
Ahmad, I., El‐Boghdadly, K., Bhagrath, R., Hodzovic, I., McNarry, A. F., Mir, F., O'Sullivan, E. P., Patel, A., Stacey, M., & Vaughan, D. (2020) · Anaesthesia · doi:10.1111/anae.14904 · Cited by 563
Labiris, N. R., & Dolovich, M. B. (2003) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2003.01893.x · Cited by 451
Bajc, M., Neilly, J. B., Miniati, M., Schuemichen, C., Meignan, M., & Jonson, B. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1170-5 · Cited by 358
The History of Therapeutic Aerosols: A Chronological Review
Stein, S. W., & Thiel, C. G. (2017) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2016.1297 · Cited by 309
The Inhalation of Drugs: Advantages and Problems
Rau, J. L. (2005) · Respiratory Care · doi:10.4187/respcare.05500367 · Cited by 279
Metadata
- Authors
- O'Callaghan, C., & Barry, P. W.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1997-04-01
- Volume
- 52
- Issue
- Supplement 2
- Pages
- S31-S44
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2152782396
- Cited by
- 293
- References
- 22
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.