CoChat

Effects of nasal CPAP on simulated driving performance in patients with obstructive sleep apnoea

Open access
George, C. F., Boudreau, A. C., Smiley, A. · 1997 · Thorax
Cited by 124

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Many patients with obstructive sleep apnoea (OSA) have difficulty in driving and experience increased automobile accidents. It has previously been shown that patients with OSA perform poorly on a laboratory based divided attention driving test (DADT). METHODS: Seventeen men with OSA of mean (SD) age 49.7 (11.2) years and an initial apnoea/hypopnoea index (AHI) of 73.0 (28.9) were restudied from one to 12 (mean (SD) 9.2 (4.2)) months after initiating treatment with nasal continuous positive airway pressure (CPAP) to examine the effects of treatment on DADT performance. Eighteen age and sex matched controls were also retested 8.4 (3.4) months after their initial tests. Following a practice session, all subjects were given the DADT for 20 minutes before each daytime nap of the standard multiple sleep latency test (MSLT). RESULTS: Untreated patients with OSA, who performed much worse than controls in all measures, improved significantly on all measures of performance, particularly in tracking error which returned to the level of controls in all but one patient. Changes in performance were much greater for patients with OSA than for controls in tracking error (mean difference 106 (95% CI 75 to 135) cm), sleep latency/ MSLT (5.3 (95% CI 2.7 to 8.0) min), number of correct responses (1.2 (95% CI 0.4 to 1.9)), number of missed responses (1.7 (95% CI 0.9 to 2.3)), and number out of bounds (10.0 (95% CI 7.9 to 13.6)), but not for response time (0.1 (95% CI -0.3 to 0.2) s). Improvement in tracking error was highly correlated with improvement in sleepiness (r = 0.65). CONCLUSIONS: Impairment in laboratory driving performance skills in patients with OSA is reversed by successful treatment with nasal CPAP. Changes in daytime sleepiness account for some but not all of the improvement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.52.7.648

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
George, C. F., Boudreau, A. C., & Smiley, A.
Venue
Thorax
Publisher
BMJ
Published
1997-07-01
Volume
52
Issue
7
Pages
648-653
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2142660770
Cited by
124
References
1
FWCI
2.68
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.