Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Auto-CPAP machines used in the treatment of obstructive sleep apnoea (OSA) are designed to vary the treatment pressure automatically in order always to apply the actually needed pressure. Consequently they should be able to achieve at least identical therapeutic effects as conventional constant pressure CPAP with a lower mean treatment pressure. The present study was designed to evaluate the therapeutic efficacy and the treatment pressure of an auto-CPAP machine (REM + auto, SEFAM) in comparison with a conventional CPAP device. METHODS: Following CPAP titration, 16 patients with OSA were allocated to receive conventional CPAP and auto-CPAP treatment under polysomnographic control in a randomised order. After each treatment the patients were asked to assess the therapy using a questionnaire; a vigilance test was also carried out and subjective daytime sleepiness was evaluated using the Epworth Sleepiness Scale (ESS). RESULTS: The mean (SD) apnoea/hypopnoea index (AHI) during auto-CPAP treatment was comparable with that during conventional CPAP treatment (4.2 (5.1) versus 3.6 (4.0)). Neither an analysis of sleep architecture nor the arousal index (7.4 (4.1) versus 7.0 (4.3)) revealed any significant differences. Daytime sleepiness measured with the ESS was also comparable (5.3 (3.4) versus 6.5 (4.2)). The vigilance test showed normal values after both treatments in all patients with no significant differences. The mean pressure during auto-CPAP treatment (8.1 (2.9) mbar), however, was significantly higher than that employed in conventional CPAP treatment (7.6 (2.7) mbar; mean difference 0.5 mbar; 95% CI 0.1 to 0.9 mbar; p < 0.05). CONCLUSIONS: Auto-CPAP was equally as effective as conventional CPAP with respect to therapeutic efficacy. The aim of reducing the treatment pressure with auto-CPAP, however, was not achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Strollo, P. J., & Rogers, R. M. (1996) · New England Journal of Medicine · doi:10.1056/nejm199601113340207 · Cited by 1,313
Upper airway closing pressures in obstructive sleep apnea
Issa, F. G., & Sullivan, C. E. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.2.520 · Cited by 240
Continuous Versus Bilevel Positive Airway Pressure for Obstructive Sleep Apnea
Reeves-Hoché, M. K., Hudgel, D. W., Meck, R., Witteman, R., Ross, A., & Zwillich, C. W. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.151.2.7842204 · Cited by 192
Cited by
Continuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001
Harsch, I. A., Schahin, S. P., Radespiel-Tröger, M., Weintz, O., Jahreiß, H., Fuchs, F. S., Wiest, G. H., Hahn, E. G., Lohmann, T., Konturek, P. C., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200302-206oc · Cited by 583
“The following night, CPAP treatment was initiated according to a standard CPAP-titration protocol ( 41 ) and on the third night, CPAP was performed with the previously established minimal effective CPAP pressure followed by a second clamp the next morning.”
MethodSelf-citationMulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
“Several studies have demonstrated the ability of auto-CPAP to determine effective CPAP in patients in whom the diagnosis of obstructive sleep apnea has been confirmed by PSG (23, 25, 31, 35, 36).”
BackgroundFlemons, W. W. (2002) · New England Journal of Medicine · doi:10.1056/nejmcp012849 · Cited by 362
Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Masa, J. F., Jiménez, A., Durán, J., Capote, F., Monasterio, C., Mayos, M., Terán, J., Hernández, L., Barbé, F., Maimó, A., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200312-1787oc · Cited by 328
Metadata
- Authors
- Ficker, J. H., Wiest, G. H., Lehnert, G., Wiest, B., & Hahn, E. G.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1998-08-01
- Volume
- 53
- Issue
- 8
- Pages
- 643-648
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2143818884
- Cited by
- 61
- References
- 5
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.