Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record.

Characteristics and toxicant emissions of JUUL electronic cigarettes

Open access
Talih, Soha, Salman, Rola, El-Hage, Rachel, Karam, Ebrahim, Karaoghlanian, Nareg, El-Hellani, Ahmad, Saliba, Najat, Shihadeh, Alan · 2019 · Tobacco Control

Abstract

Introduction: JUUL is an electronic cigarette (ECIG) with a compact form factor. It is prefilled with a liquid that is advertised to contain a high concentration of nicotine salt. JUUL commands 50% of the US ECIG market share, and its wide popularity with underage users has triggered unprecedented actions by the US FDA. Apart from its nicotine salt-containing liquid and compact form, a salient advertised design feature is a control circuit that limits the heating coil temperature, presumably reducing unwanted toxicants. In this study, several tobacco-flavoured JUUL devices were reverse engineered, and their aerosol emissions were studied. Methods: Total nicotine and its partitioning (freebase and protonated), propylene glycol/vegetable glycerin (PG/VG) ratio, and carbonyls were quantified by gas chromatography (GC) and high performance liquid chromatography (HPLC). The temperature control functionality of JUUL was investigated using a temperature-controlled bath in which the coil was submerged. Results: The liquid nicotine concentration was found to be 69 mg/mL, and the liquid and aerosol PG/VG ratio was found to be 30/70. In 15 puffs, JUUL emitted 2.05 (0.08) mg of nicotine, overwhelmingly in the protonated form. Carbonyl yields were significantly lower than those reported for combustible cigarettes, but similar to other closed-system ECIG devices. The heating coil resistance was 1.6 (0.66) Ohm, while the maximum power delivered by the JUUL device was 8.1 W. The control circuit limited the peak operating temperature to approximately 215C. Conclusions: JUUL emits a high-nicotine concentration aerosol predominantly in the protonated form. JUUL’s nicotine-normalised formaldehyde and total aldehyde yields are lower than other previously studied ECIGs and combustible cigarettes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/tobaccocontrol-2018-054616

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Talih, S., Salman, R., El-Hage, R., Karam, E., Karaoghlanian, N., El-Hellani, A., Saliba, N., & Shihadeh, A.
Venue
Tobacco Control
Publisher
BMJ
Published
2019-02-11
Volume
28
Issue
6
Pages
678-680
ISSN
  • 0964-4563 (ISSN-L)
  • 1468-3318
OpenAlex
W2911781298
Cited by
174
References
0
FWCI
15.86
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characteristics and toxicant emissions of JUUL electronic cigarettes. https://app.cochat.ai/papers/10.1136/tobaccocontrol-2018-054616
The paper
Talih, S., Salman, R., El-Hage, R., Karam, E., Karaoghlanian, N., El-Hellani, A., Saliba, N., & Shihadeh, A. (2019). Characteristics and toxicant emissions of JUUL electronic cigarettes. Tobacco Control. https://doi.org/10.1136/tobaccocontrol-2018-054616

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.