Can measures of critical power precisely estimate the maximal metabolic steady-state?
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Critical power (CP) conceptually represents the highest power output (PO) at physiological steady-state. In cycling exercise, CP is traditionally derived from the hyperbolic relationship of ∼5 time-to-exhaustion trials (TTE) (CP HYP). Recently, a 3-min all-out test (CP 3MIN) has been proposed for estimation of CP as well the maximal lactate steady-state (MLSS). The aim of this study was to compare the POs derived from CP HYP, CP 3MIN, and MLSS, and the oxygen uptake and blood lactate concentrations at MLSS. Thirteen healthy young subjects (age, 26 ± 3years; mass, 69.0 ± 9.2 kg; height, 174 ± 10 cm; maximal oxygen uptake, 60.4 ± 5.9 mL·kg−1·min−1) were tested. CP HYP was estimated from 5 TTE. CP 3MIN was calculated as the mean PO during the last 30 s of a 3-min all-out test. MLSS was the highest PO during a 30-min ride where the variation in blood lactate concentration was ≤ 1.0 mmol·L−1 during the last 20 min. PO at MLSS (233 ± 41 W; coefficient of variation (CoV), 18%) was lower than CP HYP (253 ± 44 W; CoV, 17%) and CP 3MIN (250 ± 51 W; CoV, 20%) (p < 0.05). Limits of agreement (LOA) from Bland–Altman plots between CP HYP and CP 3MIN (–39 to 31 W), and CP 3MIN and MLSS (–29 to 62 W) were wide, whereas CP HYP and MLSS presented the narrowest LOA (–7 to 48 W). MLSS yielded not only the maximum PO of stable blood lactate concentration, but also stable oxygen uptake. In conclusion, POs associated to CP HYP and CP 3MIN were larger than those observed during MLSS rides. Although CP HYP and CP 3MIN were not different, the wide LOA between these 2 tests and the discrepancy with PO at MLSS questions the ability of CP measures to determine the maximal physiological steady-state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Binder, R. K., Wonisch, M., Corra, U., Cohen-Solal, A., Vanhees, L., Saner, H., & Schmid, J.-P. (2008) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328304fed4 · Cited by 487
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Self-citation
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
The maximal metabolic steady state: redefining the ‘gold standard’
Jones, A. M., Burnley, M., Black, M. I., Poole, D. C., & Vanhatalo, A. (2019) · Physiological Reports · doi:10.14814/phy2.14098 · Cited by 298
KEIR, D. A., POGLIAGHI, S., & MURIAS, J. M. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001698 · Cited by 65
Self-citationQuadriceps muscles O2 extraction and emg breakpoints during a ramp incremental test
Iannetta, D., Qahtani, A., Millet, G. Y., & Murias, J. M. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00686 · Cited by 43
“…as current models to describe the above mentioned breakpoints have linked the [HHb]BP and the RCP, at least in the VL muscle, to the maximal lactate steady state (MLSS) (Keir et al., 2015) which demarcates the upper boundary of prolonged sustainable performance (Mattioni Maturana et al., 2016).”
BackgroundSelf-citationCaen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04942-2 · Cited by 41
Metadata
- Authors
- Mattioni Maturana, F., Keir, D. A., McLay, K. M., & Murias, J. M.
- Venue
- Applied Physiology, Nutrition, and Metabolism
- Publisher
- Canadian Science Publishing
- Published
- 2016-11
- Volume
- 41
- Issue
- 11
- Pages
- 1197-1203
- ISSN
- 1715-5312 (ISSN-L)
- 1715-5320
- OpenAlex
- W2507984074
- Cited by
- 69
- References
- 3
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can measures of critical power precisely estimate the maximal metabolic steady-state? https://app.cochat.ai/papers/10.1139/apnm-2016-0248
- The paper
- Mattioni Maturana, F., Keir, D. A., McLay, K. M., & Murias, J. M. (2016). Can measures of critical power precisely estimate the maximal metabolic steady-state? Applied Physiology, Nutrition, and Metabolism. https://doi.org/10.1139/apnm-2016-0248
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.