CoChat

Can measures of critical power precisely estimate the maximal metabolic steady-state?

Mattioni Maturana, Felipe, Keir, Daniel A., McLay, Kaitlin M., Murias, Juan M. · 2016 · Applied Physiology, Nutrition, and Metabolism
Cited by 69

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Critical power (CP) conceptually represents the highest power output (PO) at physiological steady-state. In cycling exercise, CP is traditionally derived from the hyperbolic relationship of ∼5 time-to-exhaustion trials (TTE) (CP HYP). Recently, a 3-min all-out test (CP 3MIN) has been proposed for estimation of CP as well the maximal lactate steady-state (MLSS). The aim of this study was to compare the POs derived from CP HYP, CP 3MIN, and MLSS, and the oxygen uptake and blood lactate concentrations at MLSS. Thirteen healthy young subjects (age, 26 ± 3years; mass, 69.0 ± 9.2 kg; height, 174 ± 10 cm; maximal oxygen uptake, 60.4 ± 5.9 mL·kg−1·min−1) were tested. CP HYP was estimated from 5 TTE. CP 3MIN was calculated as the mean PO during the last 30 s of a 3-min all-out test. MLSS was the highest PO during a 30-min ride where the variation in blood lactate concentration was ≤ 1.0 mmol·L−1 during the last 20 min. PO at MLSS (233 ± 41 W; coefficient of variation (CoV), 18%) was lower than CP HYP (253 ± 44 W; CoV, 17%) and CP 3MIN (250 ± 51 W; CoV, 20%) (p < 0.05). Limits of agreement (LOA) from Bland–Altman plots between CP HYP and CP 3MIN (–39 to 31 W), and CP 3MIN and MLSS (–29 to 62 W) were wide, whereas CP HYP and MLSS presented the narrowest LOA (–7 to 48 W). MLSS yielded not only the maximum PO of stable blood lactate concentration, but also stable oxygen uptake. In conclusion, POs associated to CP HYP and CP 3MIN were larger than those observed during MLSS rides. Although CP HYP and CP 3MIN were not different, the wide LOA between these 2 tests and the discrepancy with PO at MLSS questions the ability of CP measures to determine the maximal physiological steady-state.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1139/apnm-2016-0248

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 69

Metadata

Authors
Mattioni Maturana, F., Keir, D. A., McLay, K. M., & Murias, J. M.
Venue
Applied Physiology, Nutrition, and Metabolism
Published
2016-11
Volume
41
Issue
11
Pages
1197-1203
ISSN
  • 1715-5312 (ISSN-L)
  • 1715-5320
OpenAlex
W2507984074
Cited by
69
References
3
FWCI
13.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Can measures of critical power precisely estimate the maximal metabolic steady-state? https://app.cochat.ai/papers/10.1139/apnm-2016-0248
The paper
Mattioni Maturana, F., Keir, D. A., McLay, K. M., & Murias, J. M. (2016). Can measures of critical power precisely estimate the maximal metabolic steady-state? Applied Physiology, Nutrition, and Metabolism. https://doi.org/10.1139/apnm-2016-0248

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.