CoChat

Principles, Techniques, and Limitations of Near Infrared Spectroscopy

Ferrari, Marco, Mottola, Leonardo, Quaresima, Valentina · 2004 · Canadian Journal of Applied Physiology

The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.

Abstract

In the last decade the study of the human brain and muscle energetics underwent a radical change, thanks to the progressive introduction of noninvasive techniques, including near-infrared (NIR) spectroscopy (NIRS). This review summarizes the most recent literature about the principles, techniques, advantages, limitations, and applications of NIRS in exercise physiology and neuroscience. The main NIRS instrumentations and measurable parameters will be reported. NIR light (700-1000 nm) penetrates superficial layers (skin, subcutaneous fat, skull, etc.) and is either absorbed by chromophores (oxy- and deoxyhemoglobin and myoglobin) or scattered within the tissue. NIRS is a noninvasive and relatively low-cost optical technique that is becoming a widely used instrument for measuring tissue O 2 saturation, changes in hemoglobin volume and, indirectly, brain/muscle blood flow and muscle O 2 consumption. Tissue O 2 saturation represents a dynamic balance between O 2 supply and O 2 consumption in the small vessels such as the capillary, arteriolar, and venular bed. The possibility of measuring the cortical activation in response to different stimuli, and the changes in the cortical cytochrome oxidase redox state upon O 2 delivery changes, will also be mentioned. Key words: tissue oximetry, oxidative metabolism, optical imaging, blood flow, oxygen consumption, exercise physiology

Overview

Integrity signals

Registry

Crossref · 10.1139/h04-031

Cites

114 of 114 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 114 references

Research works printed but not linked: 6

  1. Bangsbo J., 2000, Am. J. Physiol., 279, R899
  2. McCully K.K., 2000, Exerc. Sport Sci. Rev., 28, 123
  3. Obrig H., 2003, J. Cereb. Blood Flow Metab., 23, 1, 10.1097/01.wcb.0000043472.45775.29 · DOI · Paper page
  4. Richardson R.S., 2002, Am. J. Physiol., 283, R1131
  5. Springett R., 2000, Am. J. Physiol., 279, H2202
  6. Tran T.K., 1999, Am. J. Physiol., 276, R1682

Cited by

See all 1,000

Metadata

Authors
Ferrari, M., Mottola, L., & Quaresima, V.
Affiliations
  • University of L'Aquila (IT)
  • Casa Sollievo della Sofferenza (IT)
  • Kyoto University (JP)
Venue
Canadian Journal of Applied Physiology
Published
2004-08-01
Volume
29
Issue
4
Pages
463-487
ISSN
1066-7814 (ISSN-L)
OpenAlex
W2130603606
Cited by
997
References
114
Citations by year
2026: 35 · 2025: 51 · 2024: 44 · 2023: 58 · 2022: 53 · 2021: 46 · 2020: 53 · 2019: 55 · 2018: 54 · 2017: 63 · 2016: 48 · 2015: 52 · 2014: 36 · 2013: 56 · 2012: 68
FWCI
4.61
Type
journal article
Language
en
Open access
closed
Licence
www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
Locations
  • Canadian Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
Funders
U.S. Food and Drug Administration
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
Keywords
near-infrared spectroscopy, tissue oxygen saturation, hemoglobin, myoglobin, muscle oxygen consumption, cerebral blood flow, brain energy metabolism, cortical activation, cytochrome c oxidase, light scattering, exercise physiology, non-invasive optical measurement
MeSH terms
Blood Volume, Cerebral Cortex, Cerebrovascular Circulation, Humans, Oximetry, Oxygen Consumption, Regional Blood Flow, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.